Analysis of Implantable Cardioverter Defibrillator Therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial
- 5 September 2003
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 14 (9) , 940-948
- https://doi.org/10.1046/j.1540-8167.2003.01554.x
Abstract
Introduction: The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood. Methods and Results: The therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow‐up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia. Conclusion: Delivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided. (J Cardiovasc Electrophysiol, Vol. 14, pp. 940‐948, September 2003)Keywords
This publication has 37 references indexed in Scilit:
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999
- Enhanced Detection Criteria in Implantable DefibrillatorsJournal of Cardiovascular Electrophysiology, 1998
- Survey of Cardiac Pacing and Defibrillation in the United States in 1993The American Journal of Cardiology, 1996
- Classification of death in antiarrhythmia trialsJournal of the American College of Cardiology, 1996
- Motor vehicle accidents in patients with an implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1995
- Smooth muscle cell proliferation and restenosis after stand alone coronary excimer laser angioplastyJournal of the American College of Cardiology, 1991
- Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapyJournal of the American College of Cardiology, 1991
- Cardiac rhythm precipitating automatic implantable cardioverter-defibrillator discharge in outpatients as detected from transtelephonic electrocardiographs recordingsThe American Journal of Cardiology, 1991
- Actuarial Incidence and Pattern of Occurrence of Shocks Following Implantation of the Automatic Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1989
- Time to first shock and clinical outcome in patients receiving an automatic implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1989