Pituitary adenomas: automatic static perimetry and Goldmann perimetry. A comparative study of 345 visual field charts.
Open Access
- 1 April 1991
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 75 (4) , 219-221
- https://doi.org/10.1136/bjo.75.4.219
Abstract
In a series of 81 cases of pituitary adenoma 345 charts of visual field performed with static automatic perimetry (AP) on the Vision Monitor and Goldmann perimetry (GP) were compared. Generally both methods were equivalent in the detection of chiasmal compression. The charts were divided into two groups: (A) 208 charts and (B) 137 charts according to the number of isoptres investigated: two (V4, 112) or three (V4, 112, 12). In group A the AP was more often altered than the GP, and the difference was statistically significant (p less than 0.001). In group B the GP seemed more effective, but the number of questionable cases was greater and the difference was not statistically significant. When the most internal isoptre of GP was outside the central 30 degrees, AP was more often abnormal (29%) than GP (2.2%), and the difference was statistically significant (chi 2, p less than 0.001). Within the central 30 degrees the GP seemed more often to be altered (23% of cases) than the AP (19.4%), but one-third of the cases were questionable. Within the central 30 degrees both techniques gave identical results and there was no statistically significant difference. The discrepancies between both static and kinetic techniques are an argument for their complementary use.Keywords
This publication has 9 references indexed in Scilit:
- SPATIAL CONTRAST SENSITIVITY IN MULTIPLE-SCLEROSIS1990
- Pseudotumor cerebri Longitudinal study using contrast sensitivity and automated static perimetryNeuro-Ophthalmology, 1990
- A Clinical Comparison of Visual Field Testing With a New Automated Perimeter, the Humphrey Field Analyzer, and the Goldmann PerimeterOphthalmology, 1985
- Comparison of manual Goldmann and automated static visual fields using the Dicon 2000 perimeter in the detection of chiasmal tumors.1984
- A modified computerized perimeter and its use in neuro-ophthalmic patientsNeuro-Ophthalmology, 1981
- Statokinetic Dissociation in Lesions of the Anterior Visual PathwaysArchives of Ophthalmology (1950), 1980
- Computerized Perimetry in Neuro-OphthalmologyOphthalmology, 1979
- Clinical Experiences with the Use of an Automated Perimeter (Otopus) in the Diagnosis and Management of Patients With Glaucoma and Neurologic DiseasesOphthalmology, 1979
- Quantitative Perimetry in Compressive Optic Neuropathy and Optic NeuritisArchives of Ophthalmology (1950), 1978