Determination of cardiac contractility in awake unsedated mice with a fluid-filled catheter
- 1 February 2004
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 286 (2) , H806-H814
- https://doi.org/10.1152/ajpheart.00291.2003
Abstract
Today, cardiac contractility in mice is exclusively measured under anesthesia or in sedated animals because the catheters available are too rigid to be used in awake mice. We therefore developed a new catheter (Pebax 03) to measure cardiac contractility in conscious mice. In this study, we evaluated the accuracy and utility of this new catheter for assessment of cardiac contractility in anesthetized and conscious mice. With the use of a balloon-pop test, the Pebax catheter with an inner diameter of 0.3 mm was found to exhibit a high natural frequency, a low damping coefficient, and a flat frequency of up to 50.5 ± 0.6 Hz. Under anesthesia (0.5% or 1.0% halothane), no difference was found in heart rate (HR), left ventricular (LV) systolic pressure (LVSP), the maximum rates of LV pressure rise and fall (LV dP/dtmax and LV dP/dtmin, respectively), ejection time (ET), and isovolumic relaxation time constant (τ) when measured with either the 1.4-Fr Millar or Pebax 03 catheter. However, when HR, LVSP, LV dP/dtmax, and LV dP/dtmin were recorded with the Pebax catheter in awake mice, values were significantly higher, and ET and τ were lower, than under anesthesia, suggesting a major impact of anesthesia on these parameters. The Pebax catheter was also used in a normotensive one-renin gene mouse model of cardiac hypertrophy induced by DOCA and salt. In this model, DOCA-salt induced a severe decrease in cardiac contractility in the absence of changes in blood pressure. These data demonstrate that cardiac contractility can be measured very accurately in conscious mice. This new device can be of great help in the investigation of cardiac function in normal and genetically engineered mice.Keywords
This publication has 37 references indexed in Scilit:
- Enhancement of Contractility With Sustained Afterload in the Intact Murine HeartCirculation, 2003
- Blood Pressure, Cardiac, and Renal Responses to Salt and Deoxycorticosterone Acetate in MiceJournal of the American Society of Nephrology, 2002
- Cardiac hypertrophy and failure: lessons learned from genetically engineered miceActa Physiologica Scandinavica, 2001
- Non-invasive echocardiographic studies in miceLife Sciences, 2001
- Effects of Chronicβ-Adrenergic Receptor Stimulation in MiceJournal of Molecular and Cellular Cardiology, 1997
- MLP-Deficient Mice Exhibit a Disruption of Cardiac Cytoarchitectural Organization, Dilated Cardiomyopathy, and Heart FailureCell, 1997
- Elevated blood pressure and enhanced myocardial contractility in mice with severe IGF-1 deficiency.Journal of Clinical Investigation, 1996
- Enhanced Myocardial Function in Transgenic Mice Overexpressing the β 2 -Adrenergic ReceptorScience, 1994
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981
- Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.Journal of Clinical Investigation, 1976