Abstract
A method is described in which smears on slides, which had been examined previously in a direct fluorescence antibody (DFA) test for Chlamydia trachomatis, were tested by the polymerase chain reaction (PCR). Twenty four (73%) of 33 smears which contained fewer than 10 elementary bodies when examined by the DFA test were positive by the PCR. Of the nine negative smears, seven contained only one or two elementary bodies. However, single elementary bodies were detected by the PCR in seven of the 24 positive samples. Fifteen smears were negative by both methods. The ability to detect small numbers of elementary bodies by the PCR and its specificity for negative smears indicates its potential for retrospective analysis of stored, archival smears on slides.Keywords
This publication has 4 references indexed in Scilit:
- Detection of Chlamydia trachomatis by the polymerase chain reaction in swabs and urine from men with non-gonococcal urethritis.Journal of Clinical Pathology, 1991
- Detection of human papilloma virus in paraffin-embedded tissue using the polymerase chain reaction.The Journal of Experimental Medicine, 1988
- CHLAMYDIA TRACHOMATIS AND REACTIVE ARTHRITIS: THE MISSING LINKThe Lancet, 1987
- Sensitivity of detecting Chlamydia trachomatis elementary bodies in smears by use of a fluorescein labelled monoclonal antibody: comparison with conventional chlamydial isolation.Journal of Clinical Pathology, 1984