A block detector for a multislice, depth-of-interaction MR-compatible PET
- 11 April 2005
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 52 (1) , 33-37
- https://doi.org/10.1109/tns.2004.843091
Abstract
We proposed and tested the a block detector for a multislice, depth-of-interaction (DOI) MR-compatible positron emission tomography (PET). The detector consists of a block detector, four optical fibers and photo-multiplier tubes (PMTs). The block detector is a lutetium oxyorthosilicate (LSO) DOI detector comprising eight LSOs arranged in a 2/spl times/2/spl times/2 matrix based on the concept proposed by Murayama et al. The size of a single scintillator of a prototype block detector was 2/spl times/2/spl times/2 mm. The scintillation photons are collected from the side of the scintillator block detector and are transferred to four channels of the position-sensitive PMT (PSPMT) using four optical fibers several meters long. The outputs of the PSPMT signals are calculated to determine the position of gamma interaction in the block detector. Results show that although the light loss from using the fiber was around 90%, there were sufficient transferred scintillation photons to obtain the photo-peak and to calculate the position of gamma interaction in the block detector with reasonable separation. We also modified the block detector to improve the performance of the detector. The size of a single scintillator of the modified block detector was enlarged to be 2.5 mm (transaxial) /spl times/ 3.5 mm (axial) /spl times/ 3.5 mm (depth) to improve the sensitivity. Good position responses as well as time resolution of 5.6-ns full-width at half-maximum (FWHM) were obtained for the modified block detector. With these results, we conclude that a two-rings, two-layer DOI-MR-compatible PET can be realized using the proposed block detector.Keywords
This publication has 11 references indexed in Scilit:
- Scintillator selection for MR-compatible gamma detectorsIEEE Transactions on Nuclear Science, 2003
- The ECAT HRRT: an example of NEMA scatter estimation issues for LSO based PET systemsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- A depth of interaction detector for PET with GSO crystals doped with different amounts of CeIEEE Transactions on Nuclear Science, 2002
- Giant Birefringent Optics in Multilayer Polymer MirrorsScience, 2000
- Design of a small animal MR compatible PET scannerIEEE Transactions on Nuclear Science, 1999
- Depth encoding multicrystal detectors for PETIEEE Transactions on Nuclear Science, 1998
- Simultaneous PET and MR imagingPhysics in Medicine & Biology, 1997
- MicroPET: a high resolution PET scanner for imaging small animalsIEEE Transactions on Nuclear Science, 1997
- PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat heartsNMR in Biomedicine, 1997
- Design considerations and initial performance of a 1.2 cm/sup 2/ beta imaging intra-operative probeIEEE Transactions on Nuclear Science, 1996