Use of osmotically active agents to alter optical properties of tissue: Effects on the detected fluorescence signal measured through skin
Open Access
- 20 September 2001
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 29 (3) , 213-220
- https://doi.org/10.1002/lsm.1110
Abstract
Background and Objective: Hyper‐osmotic chemical agents were used to study the effects of transient tissue scattering on the remitted fluorescence emission intensity from a target placed under a tissue sample.Study Design/Materials and Methods: A fluorescent film was placed underneath in vitro and in vivo samples of hamster skin, and the remitted fluorescent signal traveling to the tissue surface was monitored over time as the tissue was treated with an osmotically active agent.Results: The detected fluorescent signal increased as the scattering in tissue samples was substantially reduced. The increase was greater for dimethyl sulfoxide than glucose or glycerol. It was not statistically different between in vivo skin and in vitro skin.Conclusions: The study shows how chemical agents can be used to improve the detected signal for a specific optical application. It could be useful in a number of optical therapeutic and diagnostic applications that can benefit from an increase in the penetration depth of light. Lasers Surg. Med. 29:213–220, 2001.Keywords
This publication has 19 references indexed in Scilit:
- Fluorescence Excitation Emission Matrices of Human Tissue: A System for in vivo Measurement and Method of Data AnalysisApplied Spectroscopy, 1999
- Long-term storage of tissues by cryopreservation: critical issuesPublished by Elsevier ,1999
- Dependence of tissue optical properties on solute-induced changes in refractive index and osmolarityJournal of Biomedical Optics, 1996
- Group refractive index measurement of dry and hydrated type I collagen films using optical low-coherence reflectometryJournal of Biomedical Optics, 1996
- Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infraredOptics Letters, 1994
- Relation between fluorescence spectra of dilute and turbid samplesApplied Optics, 1994
- Optically Dilute, Absorbing, and Turbid Phantoms for Fluorescence Spectroscopy of Homogeneous and Inhomogeneous SamplesApplied Spectroscopy, 1993
- Refractive index of some mammalian tissues using a fiber optic cladding methodApplied Optics, 1989
- A transparent access chamber for the rat dorsal skin foldMicrovascular Research, 1979