Aortic Aneurysm Size and Graft Behavior after Endovascular Stent-Grafting: Clinical Experiences and Observations over 3 Years
- 1 June 2000
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 7 (3) , 167-176
- https://doi.org/10.1177/152660280000700301
Abstract
Purpose: To assess the long-term safety and efficacy of aortic endografts in terms of clinical outcome, continuing aneurysm exclusion, and changes of aneurysm size and graft configuration. Methods: Between August 1994 and July 1997, 190 patients (176 men; mean age 68.7 years, range 40–87) with aortic and aortoiliac aneurysms were treated with endovascular stent-grafts (Stentor, Vanguard, and EGS) in a tertiary care municipal hospital setting. Follow-up involved clinic visits every 3 to 6 months with contrast-enhanced computed tomography (CT), color duplex, and plain abdominal radiographs at regular intervals; angiography was used selectively. All data were collected prospectively and entered into a computerized database. Results: Implantation was possible in 188 (98.9%) patients. Early conversion to open surgical repair was required in 14 (7.4%) patients. Primary endoleaks were detected in 32 (16.8%) patients. Perioperative mortality was 0.53% (1/190). During follow-up, 17 (8.9%) additional patients were converted to open repair over a mean 20.9 months. Thirty-seven secondary procedures to treat endoleaks and pelvic outflow occlusions were performed in 30 (15.8%) patients. Changes in stent configuration suggestive of endograft disintegration were observed in 31 (29.8%) of 104 abdominal radiographs. Intraluminal layering of thrombus was seen on contrast-enhanced CT images in 20 patients. A significant trend (χ24 = 12.34, p < 0.025) toward aneurysm enlargement was seen in patients with persistent endoleaks at a mean 18-month follow-up. Conclusions: Although endoleaks after aortic stent-graft placement tend to cause ongoing aneurysm growth, we have also observed aneurysm shrinkage despite ongoing endoleak. The presence or absence of an endoleak in itself may be a poor predictor of successful stent-graft therapy. Lifelong surveillance is needed to assure successful aneurysm exclusion and stability or shrinkage of the aneurysm sac. Technical improvements in stent materials and design are necessary to guarantee long-term stability and safety of the device.Keywords
This publication has 19 references indexed in Scilit:
- Abdominal Aortic Aneurysm Measurements for Endovascular Repair: Intra- and Interobserver Variability of CT MeasurementsEuropean Journal of Vascular and Endovascular Surgery, 1999
- Endotension: An Explanation for Continued AAA Growth after Successful Endoluminal RepairJournal of Endovascular Therapy, 1999
- Endotension after Endovascular Aneurysm Repair: Definition, Classification, and Strategies for Surveillance and InterventionJournal of Endovascular Therapy, 1999
- Abdominal Aortic AneurysmAnnals of Surgery, 1999
- Realistic Expectations for Patients with Stent-graft Treatment of Abdominal Aortic Aneurysms. Results of a European Multicentre RegistryEuropean Journal of Vascular and Endovascular Surgery, 1999
- Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studiesBritish Journal of Surgery, 1999
- Three-Year Experience with Modular Stent-Graft Devices for Endovascular AAA TreatmentJournal of Endovascular Therapy, 1997
- Reduction in aortic aneurysm size: Early results after endovascular graft placementJournal of Vascular Surgery, 1997
- A Prospective Study of Changes in Morphology and Dimensions of Abdominal Aortic Aneurysms following Endoluminal Repair: A Preliminary ReportJournal of Endovascular Therapy, 1995