Adaptive whitening of the electromyogram to improve amplitude estimation
- 1 June 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 47 (6) , 709-719
- https://doi.org/10.1109/10.844217
Abstract
Previous research showed that whitening the surface electromyogram (EMG) can improve EMG amplitude estimation (where EMG amplitude is defined as the time-varying standard deviation of the EMG). However, conventional whitening via a linear filter seems to fail at low EMG amplitude levels, perhaps due to additive background noise in the measured EMG. This paper describes an adaptive whitening technique that overcomes this problem by cascading a nonadaptive whitening filter, an adaptive Wiener filter, and an adaptive gain correction. These stages can be calibrated from two, five second duration, constant-angle, constant-force contractions, one at a reference level [e.g., 50% maximum voluntary contraction (MVC)] and one at 0% MVC. In experimental studies, subjects used real-time EMG amplitude estimates to track a uniform-density, band-limited random target. With a 0.25-Hz bandwidth target, either adaptive whitening or multiple-channel processing reduced the tracking error roughly half-way to the error achieved using the dynamometer signal as the feedback. At the 1.00-Hz bandwidth, all of the EMG processors had errors equivalent to that of the dynamometer signal, reflecting that errors in this task were dominated by subjects' inability to track targets at this bandwidth. Increases in the additive noise level, smoothing window length, and tracking bandwidth diminish the advantages of whitening.Keywords
This publication has 24 references indexed in Scilit:
- EMG amplitude estimation with adaptive smoothing window lengthPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Electromyogram amplitude estimation with adaptive smoothing window lengthIEEE Transactions on Biomedical Engineering, 1999
- PC-based workstation for real-time acquisition, processing, and display of electromyogram signalsComputer Standards & Interfaces, 1999
- Relating agonist-antagonist electromyograms to joint torque during isometric, quasi-isotonic, nonfatiguing contractionsIEEE Transactions on Biomedical Engineering, 1997
- Adaptive filtering of the electromyographic signal for prosthetic control and force estimationIEEE Transactions on Biomedical Engineering, 1995
- Comparison of signal-to-noise ratio of myoelectric filters for prosthesis controlJournal of Rehabilitation Research and Development, 1992
- Analysis of a Digital EMG Signal Processor in Dynamic ConditionsIEEE Transactions on Biomedical Engineering, 1985
- Signal Processing for Proportional Myoelectric ControlIEEE Transactions on Biomedical Engineering, 1984
- Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part I: Derivation of the Optimal MyoprocessorIEEE Transactions on Biomedical Engineering, 1980