Reticulocyte counting in thalassemic and other conditions with the R-1000 Sysmex analyzer
- 1 October 1991
- journal article
- Published by Springer Nature in Annals of Hematology
- Vol. 63 (4) , 218-222
- https://doi.org/10.1007/bf01703447
Abstract
Precise reticulocyte counts are difficult to obtain by the manual method when their percentage in the blood is low or normal. In these instances, rapid reticulocyte counting by flow cytometry appears to offer more accuracy and precision. The purpose of this study was to establish reticulocyte counts in heterozygous β-thalassemia for reference purposes and to evaluate the performance of the recently introduced apparatus R-1000 (Sysmex) in the very heterogeneous thalassemic and sickle-cell syndromes. We studied a total of 364 samples; 102 heterozygous β-thalassemia carriers, 180 normal matched controls, 36 patients with thalassemia major or intermedia, and 46 patients with various sickle-cell syndromes. Reticulocyte counts (both as percentage and as total number) were higher in heterozygous β-thalassemia than in normal controls (pp<0.001). These results confirm the proposed slightly increased erythropoietic activity in heterozygous β-thalassemia carriers. A drawback of the technique is that the reticulocyte-platelet discrimination error is signaled frequently in all conditions displaying a marked red cell heterogeneity, especially when these are associated with high reticulocyte numbers. This calls probably for readjustment of the corresponding algorithm. In addition, all these conditions show a significantly increased auramine-O mature red-cell nonspecific fluorescence.Keywords
This publication has 21 references indexed in Scilit:
- Serum Erythropoietin Levels in β‐ThalassemiaAnnals of the New York Academy of Sciences, 1990
- Evaluation of the Sysmex R-1000®: An Automated Reticulocyte AnalyzerAmerican Journal of Clinical Pathology, 1990
- Evaluation of reticulocyte counts by flow cytometry in a routine laboratoryAmerican Journal of Hematology, 1990
- An Automated Optoelectronic Reticulocyte CounterAmerican Journal of Clinical Pathology, 1989
- Enumeration of Reticulocytes Using Fluorescence-Activated Flow CytometryPathology and Immunopathology Research, 1988
- Computerized Diagnosis of Anemias Based Upon Red Blood Cell Indices and Related Cell CountsLaboratory Medicine, 1987
- Thiazole orange: A new dye for reticulocyte analysisCytometry, 1986
- Simultaneous reticulocyte and platelet counting on a clinical flow cytometerAmerican Journal of Hematology, 1985
- Clinical and Haematological Data in 254 Cases of Beta‐Thalassaemia Trait in ItalyBritish Journal of Haematology, 1976
- Haematological Data in 312 Cases of β‐Thalassaemia Trait in ThailandBritish Journal of Haematology, 1973