The Effects of Pulsatile Flow Upon Renal Tissue Perfusion During Cardiopulmonary Bypass: A Comparative Study of Pulsatile and Nonpulsatile Flow
- 1 January 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 51 (1) , 30-36
- https://doi.org/10.1097/01.mat.0000150324.02040.b4
Abstract
This study was conducted to directly compare the effects of pulsatile and nonpulsatile blood flow in the extracorporeal circulation upon renal tissue perfusion by using a tissue perfusion measurement system. A total cardiopulmonary bypass circuit was constructed to accommodate twelve Yorkshire swine, weighing 20∼30 kg. Animals were randomly assigned to group 1 (n = 6, nonpulsatile centrifugal pump) or group 2 (n = 6, pulsatile T-PLS pump). A tissue perfusion measurement probe (Q-Flow 500) was inserted into the renal parenchymal tissue, and the extracorporeal circulation was maintained for an hour at a pump flow rate of 2 L/min after aortic cross-clamping. Tissue perfusion flow in the kidney was measured before bypass and every 10 minutes after bypass. Renal tissue perfusion flow was substantially higher in the pulsatile group throughout bypass (ranging 48.5-64.1 ml/min/100 g in group 1 vs. 51.0-88.1 ml/min/100 g in group 2). The intergroup difference was significant at 30 minutes (47.5 ± 18.3 ml/min/100 g in group 1 vs. 83.4 ± 28.5 ml/min/100 g in group 2; p = 0.026). Pulsatile flow achieves higher levels of tissue perfusion of the kidney during short-term extracorporeal circulation. A further study is required to observe the effects of pulsatile flow upon other vital organs and its long-term significance.Keywords
This publication has 20 references indexed in Scilit:
- Myths and Truths of Pulsatile and Nonpulsatile Perfusion During Acute and Chronic Cardiac SupportArtificial Organs, 2004
- In vivo evaluation of the pulsatile ECLS sysemJournal of Artificial Organs, 2003
- Continuous monitoring of regional cerebral blood flow: experimental and clinical validation of a novel thermal diffusion microprobeJournal of Neurosurgery, 2000
- Thermodiffusion for Continuous Quantification of Hepatic Microcirculation—Validation and Potential in Liver TransplantationMicrovascular Research, 1999
- Can We Develop a Nonpulsatile Permanent Rotary Blood Pump? Yes, We Can.Artificial Organs, 1996
- Continuous Measurement of Porcine Renal Cortex Microcirculation with Enhanced Thermal Diffusion TechnologyJournal of Surgical Research, 1996
- The effects of pulsatile and nonpulsatile systemic perfusion on renal sympathetic nerve activity in anesthetized dogsThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Pulsatile and Nonpulsatile Cardiopulmonary Bypass: Review of a Counterproductive ControversyThe Annals of Thoracic Surgery, 1983
- A Prospective Evaluation of the Pulsatile Assist DeviceThe Annals of Thoracic Surgery, 1979
- In Vivo Determination of Renal Tissue Oxygenation During Pulsatile and Nonpulsatile Left Heart BypassThe Annals of Thoracic Surgery, 1973