In Vitro Comparison of Salbutamol Hydrofluoroalkane (Airomir) Metered Dose Inhaler Aerosols Inhaled during Pediatric Tidal Breathing from Five Valved Holding Chambers
- 1 January 1999
- journal article
- research article
- Published by Mary Ann Liebert Inc in Journal of Aerosol Medicine
- Vol. 12 (4) , 285-291
- https://doi.org/10.1089/jam.1999.12.285
Abstract
Amounts of salbutamol delivered from chlorofluorocarbon (CFC)-free metered dose inhalers (MDIs) (Airomir; 3M, St. Paul, MN) in particle sizes appropriate for inhalational treatment with five common holding chambers (NES [or Nebuchamber] spacer [Astra Draco AB, Lund, Sweden], AeroChamber [Trudell Medical, London, Ontario, Canada], OptiChamber [Health-scan Products, Cedar Grove, NJ], Ventl70 spacer [Nordac Design, Waterloo, Ontario, Canada], and E-Z Spacer [WE Pharmaceuticals, Ramona, CA]) when used under simulated pediatric tidal breathing conditions were determined. Five devices of each type were tested with Airomir hydrofluoroalkane (HFA) inhalers (100 μg of salbutamol). Each device was connected to face replicas representative of 7-month-old (infant) and 2-year-old (toddler) children, and aerosol was also inhaled into an Andersen cascade impactor (Graseby Andersen, Smyrna, GA) using a valve system and simulated tidal breathing patterns representative of children of these ages. Amounts of drug inhaled in fine particles with the HFA formulation are significantly less (up to 46% less) with the E-Z Spacer (P < 0.01) compared with amounts inhaled in previous studies with the CFC formulation but are nearly the same with other holding chamber types (e.g., differing by < 6% for the AeroChamber). With the HFA formulation, the metal NES spacer delivered significantly more salbutamol in fine particles (P < 0.01) than any of the other holding chambers. Amounts of salbutamol inhaled in fine particles during pediatric tidal breathing from valved holding chambers with Airomir varies considerably between holding chamber types.Keywords
This publication has 14 references indexed in Scilit:
- Early lung absorption profile of non‐CFC salbutamol via small and large volume plastic spacer devicesBritish Journal of Clinical Pharmacology, 1998
- Inertial sizing of aerosol inhaled during pediatric tidal breathing from an MDI with attached holding chamberInternational Journal of Pharmaceutics, 1998
- Salbutamol Delivery From a Hydrofluoroalkane Pressurized Metered-Dose Inhaler in Pediatric Ventilator CircuitsChest, 1998
- Particle Size Measurements for the Space-Chamber Metered Dose Inhaler Holding Chamber Compared with Aerochamber and Metered Dose Inhaler AloneJournal of Aerosol Medicine, 1997
- Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants.Thorax, 1996
- Inhalational drug delivery from seven different spacer devices.Thorax, 1996
- Effect of Add-on Devices for Aerosol Drug Delivery: Deposition Studies and Clinical AspectsJournal of Aerosol Medicine, 1996
- Lung function measurement in awake young childrenEuropean Respiratory Journal, 1995
- Respiratory Mechanics in Infants: Physiologic Evaluation in Health and DiseaseAmerican Review of Respiratory Disease, 1993