Qualitative Detection of Tetracycline Residues in Milk with a Luminescence-Based Microbial Method: The Effect of Milk Composition and Assay Performance in Relation to an Immunoassay and a Microbial Inhibition Assay
- 1 July 2000
- journal article
- research article
- Published by Elsevier in Journal of Food Protection
- Vol. 63 (7) , 953-957
- https://doi.org/10.4315/0362-028x-63.7.953
Abstract
Performance of Tet-Lux, a newly developed microbiological test for the detection of tetracycline residues in raw milk, based on tetracycline-controlled luminescence activation of the test bacteria,...Keywords
This publication has 10 references indexed in Scilit:
- Simultaneous determination of residual tetracyclines in foods by high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Evaluation of a Modified Enzymatic Test for the Detection of Tetracyclines in MilkJournal of Food Protection, 1999
- Rapid liquid chromatographic determination of oxytetracycline in milkJournal of Chromatography A, 1999
- A Recombinant Escherichia coli Sensor Strain for the Detection of TetracyclinesAnalytical Chemistry, 1998
- Testing of Raw Milk for Tetracycline ResiduesJournal of Dairy Science, 1998
- Chromatographic methods of analysis of antibiotics in milkJournal of Chromatography A, 1998
- Antimicrobial Drug Residues in Milk and Meat: Causes, Concerns, Prevalence, Regulations, Tests, and Test PerformanceJournal of Food Protection, 1998
- Tetracycline resistance determinants: mechanisms of action, regulation of expression, genetic mobility, and distributionFEMS Microbiology Reviews, 1996
- Detection of inhibitors in milk by microbial tests A reviewMolecular Nutrition & Food Research, 1996