Scatter modelling and correction strategies in fully 3-D PET
- 1 November 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 22 (11) , 1181-1184
- https://doi.org/10.1097/00006231-200111000-00003
Abstract
PET offers the possibility of quantitative measurements of tracer concentration in vivo. However, there are several issues that must be considered in order to fully realise this potential. Whilst, a correction for a number of background and physical phenomena need to be performed, the two most significant effects are the photon attenuation in the patient and the contribution in the images of events arising from photons scattered in the patient and the gantry. The non-homogeneous distribution of attenuation within the thoracic cavity complicates the interpretation of PET images and precludes the application of simple scatter correction methods developed for homogeneous media. The development of more sophisticated techniques for quantification of PET images are still required. Recent progress in 3D PET instrumentation and image reconstructions has created a need for a concise review of the relevance and accuracy of scatter correction strategies. Improved quantification of PET images remains an area of considerable research interest and several research groups are concentrating their efforts towards the development of more accurate scatter modelling and correction algorithms.Keywords
This publication has 17 references indexed in Scilit:
- Comparative evaluation of scatter correction techniques in 3D positron emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2000
- Relevance of accurate Monte Carlo modeling in nuclear medical imagingMedical Physics, 1999
- Energy dependence of nonstationary scatter subtraction-restoration in high resolution PETIEEE Transactions on Medical Imaging, 1999
- Efficient scatter modelling for incorporation in maximum likelihood reconstruction.European Journal of Nuclear Medicine and Molecular Imaging, 1998
- Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstructionPhysics in Medicine & Biology, 1998
- Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation studyPhysics in Medicine & Biology, 1997
- Evaluation of simulation-based scatter correction for 3-D PET cardiac imagingIEEE Transactions on Nuclear Science, 1997
- Model-based scatter correction for fully 3D PETPhysics in Medicine & Biology, 1996
- A Monte Carlo correction for the effect of Compton scattering in 3-D PET brain imagingIEEE Transactions on Nuclear Science, 1995
- Fast SPECT simulation including object shape dependent scatterIEEE Transactions on Medical Imaging, 1995