ORBITAL IMPLANTS AND PROSTHESES - POSTOPERATIVE COMPUTED TOMOGRAPHIC APPEARANCE
- 1 January 1985
- journal article
- research article
- Vol. 6 (3) , 403-407
Abstract
Computed tomographic (CT) scans of 19 patients with 10 right and 9 left orbital implants were reviewed. Except for orbital soft-tissue swelling due to recent surgery or infection, CT scans obtained with both the implant and prosthesis in the place showed relative symmetry of the postoperative side and the native globe. Benign air collections were often associated with either the implant or prosthesis interface or with seating of the prosthesis in the conjunctival fornices. Six patients had either cartilage, silicone or glass beads placed surgically along the orbital floor to elevate the implants, 4 having had prior depressed orbital floor fractures. CT identified implant migration in 5 patients. The orbital prosthesis, usually constructed of solid methylmethacrylate, is fitted over the implant and simulates the appearance of the eye of the contralateral side. The operative anatomy and its relation to the CT appearance of the implant and external prosthesis are reviewed.This publication has 4 references indexed in Scilit:
- Lacrimal gland and fossa masses: evaluation by computed tomography and A-mode echography.Radiology, 1983
- Blow-out fractures of the orbit: a comparison of computed tomography and conventional radiography with anatomical correlation.Radiology, 1982
- Computed tomography and ultrasound in the evaluation of orbital infection and pseudotumor.Radiology, 1982
- Computed tomography of orbital tumors, including late-generation scanning techniques.Radiology, 1982