St. Jude Medical cardiac valve replacement was performed in 791 patients: 335 had aortic, 330 mitral, and 126 had multiple valve replacements. Follow-up extended from 4 to 64 months (mean 34 months) with a cumulative postoperative survival of 2,111 patient-years. The overall actuarial survival rate at 5 years was 76% .+-. 3%. Late valve-related mortality occurred in 28 patients (1.33%/pt-yr) and was most often caused by anticoagulant-related hemorrhage. The linearized incidence of valve failure, thromboembolism, thrombotic obstruction, prosthetic valve endocarditis, periprosthetic leak, and all valve-related complications were as follows: 1.80%/pt-yr, 2.45%/pt-yr, 0.52%/pt-yr, 0.33%/pt-yr, 0.14%/pt-yr, and 4.0%/pt-yr, respectively. Actuarially, 94% .+-. 2% of patients were free of valve-related mortality at 5 years; the corresponding figures for valve failure, thromboembolism, thrombotic obstruction, and all valve-related complications were 91% .+-. 2%, 89% .+-. 2%, 96% .+-. 1%, and 83% .+-. 3%, respectively. Prosthetic valve endocarditis was uniformly fatal, and 45% of patients with thrombotic obstruction died. The greater incidence of thrombotic obstruction after mitral valve replacement was statistically significant. The performance of the St. Jude Medical valve compares most favorably with other substitute valves. Nevertheless, it retains all the imperfections and hazards of other mechanical valves, most notably, thromboembolism and thrombotic obstruction.This publication has 21 references indexed in Scilit:
- Enlargement of the narrow aortic root and oblique insertion of a St Jude prosthesis.Heart, 1983
- Ten to fifteen year reassessment of the performance characteristics of the Starr-Edwards Model 6120 mitral valve prosthesisThe Journal of Thoracic and Cardiovascular Surgery, 1983
- Assessment and Comparison of the Performance of Cardiac ValvesThe Annals of Thoracic Surgery, 1982
- THROMBOSIS OF THE BJORK-SHILEY PROSTHESIS - ILLUSTRATIVE CASES AND REVIEW OF THE LITERATURE1982
- The Ultimate Prognosis after Valve Replacement: An Assessment at Twenty YearsThe Annals of Thoracic Surgery, 1981
- THE BJORK-SHILEY VALVE - INTERMEDIATE-TERM FOLLOW-UP1981
- Thrombosed Björk-Shiley mitral prostheses.Circulation, 1980
- Ten years’ experience with the Björk-Shiley tilting disc valveThe Journal of Thoracic and Cardiovascular Surgery, 1979
- Long-term evaluation of the porcine xenograft bioprosthesisThe Journal of Thoracic and Cardiovascular Surgery, 1979
- INCIDENCE OF EMBOLI WITH CLOTH-COVERED STARR-EDWARDS VALVE WITHOUT ANTICOAGULATION AND WITH VARYING FORMS OF ANTICOAGULATION - ANALYSIS OF 183 PATIENTS FOLLOWED FOR 3 1/2 YEARS1978