Altered load history affects periprosthetic bone loss following cementless total hip arthroplasty
- 1 September 1996
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 14 (5) , 762-768
- https://doi.org/10.1002/jor.1100140513
Abstract
Dual energy x-ray absorptiometry was used to measure periprosthetic, distal femoral, and proximal tibial bone mass in the affected and contralateral limbs of eight patients 10 years after unilateral total hip arthroplasty with a cementless, porous-coated titanium alloy femoral stem. Gait analyses to assess the presence of asymmetries in loading of the lower extremities were also performed 10 years postoperatively. The patients had excellent clinical results and no other significant lower extremity pathology. On the basis of comparison of the affected and unaffected proximal femora, bone loss adjacent to the proximal medial aspect of the femoral stem was determined to be 34% (p < 0.001). However, the patients also had 16% less bone in the ipsilateral proximal tibia (p = 0.003) and 15% less bone in the ipsilateral femur 3 cm distal to the prosthesis (p = 0.007) compared with the contralateral limb. When normalized to the asymmetry in tibial bone mineral content, the estimated proximal medial periprosthetic bone loss was still statistically significant, but the magnitude was reduced from 34 to 17% (p = 0.009). The gait analyses indicated that several measures that influence the loads at the hip and knee joints were reduced in the involved limb compared with the contralateral limb. Furthermore, the bilateral difference in the vertical component of the external force acting on the proximal tibia was correlated with the bilateral difference in tibial bone mineral content (r = 0.80, p = 0.02). These data suggest that two mechanical factors, the local stress-shielding effect of the prosthesis and the global effect of decreased loading of the limb, can both make significant contributions to periprosthetic bone loss. It is apparent that the magnitude of the periprosthetic bone loss related to stress-shielding has been overestimated by as much as 50% in retrospective studies.Keywords
This publication has 28 references indexed in Scilit:
- The influence of prosthesis design on stress shielding in cementless total hip replacementThe Journal of Arthroplasty, 1994
- Adaptive bone remodeling around bonded noncemented total hip arthroplasty: A comparison between animal experiments and computer simulationJournal of Orthopaedic Research, 1993
- Bone and muscle mass after hip rearthroplasty: Controlled CT study of 12 patientsActa Orthopaedica, 1993
- Effects of material properties of femoral hip components on bone remodelingJournal of Orthopaedic Research, 1992
- Determination of bone mineral density by dual X‐ray absorptiometry in patients with uncemented total hip arthroplastyJournal of Orthopaedic Research, 1992
- Determinants of Stress ShieldingClinical Orthopaedics and Related Research, 1992
- Distal cortical hypertrophy following total hip arthroplastyThe Journal of Arthroplasty, 1988
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987
- Changes in Bone Mineral Content in the Femur Following Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1984
- Three-Dimensional Coordinate Data Processing in Human Motion AnalysisJournal of Biomechanical Engineering, 1979