Dosimetric evaluation of daily rigid and nonrigid geometric correction strategies during on‐line image‐guided radiation therapy (IGRT) of prostate cancer
- 26 December 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 34 (1) , 352-365
- https://doi.org/10.1118/1.2405325
Abstract
The purpose of this study is to evaluate a geometric image guidance strategy that simultaneously correct for various inter-fractional rigid and nonrigid geometric uncertainties in an on-line environment, using field shape corrections (called the "MU-MLC" technique). The effectiveness of this strategy was compared with two other simpler on-line image guidance strategies that are more commonly used in the clinic. To this end, five prostate cancer patients, with at least 15 treatment CT studies each, were analyzed. The prescription dose was set to the maximum dose that did not violate the rectum and bladder dose-volume constraints, and hence, was unique to each patient. Deformable image registration and dose-tracking was performed on each CT image to obtain the cumulative treatment dose distributions. From this, maximum, minimum, and mean dose, as well as generalized equivalent uniform dose (gEUD) were calculated for each image guidance strategy. As expected, some dosimetric differences in the clinical target volume (CTV) were observed between the three image guidance strategies investigated. For example, up to +/-2% discrepancy in prostate minimum dose were observed among the techniques. Of them, only the "MU -MLC" technique did not reduce the prostate minimum dose for all patients (i.e., > or = 100%). However, the differences were clinically not significant to indicate the preference of one strategy over another, when using a uniform 5 mm margin size. For the organ-at-risks (OARs), the large rectum sparing effect (< or =5.7 Gy, gEUD) and bladder overdosing effect (< or = 16 Gy, gEUD) were observed. This was likely due to the use of bladder contrast during CT simulation studies which was not done during the treatment CT studies. Therefore, ultimately, strategies to maintain relatively constant rectum and bladder volumes, throughout the treatment course, are required to minimize this effect. In conclusion, the results here suggest that simple translational corrections based on three-dimensional (3D) images is adequate to maintain target coverage, for margin sizes at least as large as 5 mm. In addition, due to large fluctuations in OAR volumes, innovative image guidance strategies are needed to minimize dose and maintain consistent sparing during the whole course of radiation therapy.Keywords
This publication has 36 references indexed in Scilit:
- Prostate position variability and dose–volume histograms in radiotherapy for prostate cancer with full and empty bladderInternational Journal of Radiation Oncology*Biology*Physics, 2006
- Application of dose compensation in image-guided radiotherapy of prostate cancerPhysics in Medicine & Biology, 2006
- Automatic re-contouring in 4D radiotherapyPhysics in Medicine & Biology, 2006
- Large deformation three-dimensional image registration in image-guided radiation therapyPhysics in Medicine & Biology, 2005
- Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patientsInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Dosimetric impact of image-guided 3D conformal radiation therapy of prostate cancerPhysics in Medicine & Biology, 2005
- Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)International Journal of Radiation Oncology*Biology*Physics, 2005
- Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapyPhysics in Medicine & Biology, 2005
- Tracking the dose distribution in radiation therapy by accounting for variable anatomyPhysics in Medicine & Biology, 2004