In image-guided radiation therapy (IGRT), volumetric information on patient anatomy at treatment conditions is made available with in-room imaging devices capable of cone-beam CT. Setup error and inter-fraction rigid motion can be corrected online. The planning margin can therefore be reduced significantly. However, to compensate for uncertainties including organ deformation and intra-fraction motion, offline evaluation and replanning are necessary. The purpose of this study is to investigate the use of an offline dose compensation technique to further reduce the margin safely. In IGRT, online CT scan, rigid image registration and setup correction are performed at each fraction. Later the regions of interest are registered offline between treatment and planning CTs using a finite element method to account for non-rigid organ motion. Cumulative dose distribution is calculated and compared with the prescription dose. The discrepancy, if found significant, is repaired using the dose compensation technique, in which the cumulative dose distribution is incorporated in adaptive IMRT planning for future fractions. Two compensation schedules were tested in this study: single compensation at the end of the treatment course and compensation performed weekly. One patient with one planning CT and 16 treatment CTs were used in this simulation study. Due to the aggressive smaller planning margin used, severe underdose was observed in the clinical target volume. The size and magnitude of the underdose were reduced substantially with online guidance but were still significant. Both dose compensation strategies were able to reduce the dose deficit to an acceptable level without additional planning margin. Weekly compensation is more biologically beneficial and can spread the execution error into multiple fractions. The offline dose compensation technique allows further margin reduction and can complement the online guidance by compensating for uncertainties that cannot be reduced online, thereby increasing the confidence in IGRT delivery.Keywords
This publication has 16 references indexed in Scilit:
- Emergent Technologies for 3-Dimensional Image-Guided Radiation DeliverySeminars in Radiation Oncology, 2005
- Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)International Journal of Radiation Oncology*Biology*Physics, 2005
- Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging deviceInternational Journal of Radiation Oncology*Biology*Physics, 2003
- Adapting inverse planning to patient and organ geometrical variation: algorithm and implementationMedical Physics, 2003
- Reducing uncertainties in volumetric image based deformable organ registrationMedical Physics, 2003
- Daily prostate targeting using implanted radiopaque markersInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58Medical Physics, 2001
- Prostate target volume variations during a course of radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 1998
- An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motionPhysics in Medicine & Biology, 1998
- Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimationInternational Journal of Radiation Oncology*Biology*Physics, 1996