Fretting wear in a modular neck hip prosthesis
- 1 May 1997
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 35 (2) , 207-216
- https://doi.org/10.1002/(sici)1097-4636(199705)35:2<207::aid-jbm9>3.0.co;2-r
Abstract
In vitro cyclic load fretting tests were conducted on a prototype of a cementless, modular neck, hip prosthesis. The study had three major objectives: to determine the amount of fretted material in the tapered-neck joint under various load cycle amplitudes, to determine the fretting damage evolution, and to determine the effect of different-sized stem bodies on the production of debris. All the tests produced some fretting microdamage on the tapered surface although the extent was quite different among test groups. The amount of abraded material increased almost linearly with the applied load magnitude but not with the number of load cycles. The amount of weight loss was higher in the large stem bodies than in the small ones. Weight loss ranged from 0.28 ± 0.10 mg for small stem bodies loaded 5.5 million times up to 2300N to 2.54 ± 0.53 mg for large stem bodies located 20 million times up to 3300N. Considering the large-size stem results, and assuming one million load cycles between 300N and 3300N to be the average yearly load history, the modular neck tapered joint would produce 0.6 mg/year of metal debris. The clinical impact of this observation is unknown; however, some of the literature on the presence of metal in patient tissues and fluids supports the hypothesis that a normal and stable prosthesis is likely to produce less than 10 mg/year of metal debris. Thus, a further production of 0.6 mg/year due to the modular neck should not have any significant effect. © 1997 John Wiley & Sons, Inc.Keywords
This publication has 26 references indexed in Scilit:
- Design-related fretting wear in modular neck hip prosthesisJournal of Biomedical Materials Research, 1996
- Wear DebrisPublished by Wolters Kluwer Health ,1994
- In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy couplingJournal of Biomedical Materials Research, 1993
- Bone resorption activity of particulate-stimulated macrophagesJournal of Bone and Mineral Research, 1993
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- Storage and elimination of titanium, aluminum, and vanadium salts, in vivoJournal of Biomedical Materials Research, 1992
- Material effects in fretting wear: application to iron, titanium, and aluminum alloysMetallurgical Transactions A, 1991
- Cementless Total Joint Arthroplasty Prostheses With Titanium-Alloy Articular SurfacesPublished by Wolters Kluwer Health ,1990
- The biological response to titanium and titanium-aluminium-vanadium alloy particlesBiomaterials, 1985
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977