CCD camera for dual-energy digital subtraction angiography
- 1 January 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (4) , 747-752
- https://doi.org/10.1109/42.476115
Abstract
A motion immune dual-energy subtraction technique in which X-ray tube voltage and beam filtration were switched at 30 Hz between 60 kVp (2.0 mm Al filter) and 120 kVp (2.00 mm Al+2.5 mm Cu filter) was previously reported. In this study the effects of camera lag on the dual-energy iodine signal is investigated. The temporal lag of the lead oxide vidicon tested reduced the dual-energy iodine signal by a factor of 2.3, as compared to a mode that included 4 scrub frames between low- and high-energy images, for an iodine phantom with thicknesses of 0-86.0 mg/cm(2), imaged over a 15 cm thick Lucite phantom. On the other hand, the Charge-Coupled Device (CCD) camera has inherently no temporal lag and its versatile scanning characteristics make it near ideal for dual-energy DSA. The CCD camera eliminates the reduction of dual-energy iodine signal, since it does not mix low- and high-energy image data. Another benefit of the CCD camera is that the separation time between low and high-energy images is not limited to the frame period, as is the lead oxide vidicon; and as small as a 5-msec time difference is possible. The short time interval between low and high-energy images minimizes motion misregistration artifacts. Due to these advantages, the CCD camera significantly improves the utility of dual-energy DSA.Keywords
This publication has 16 references indexed in Scilit:
- Absolute volumetric blood flow measurements using dual‐energy digital subtraction angiographyMedical Physics, 1993
- Limitations of the lead oxide vidicon for dual-energy digital subtraction angiographyIEEE Transactions on Medical Imaging, 1991
- Quantitative Dual-Energy Coronary ArteriographyInvestigative Radiology, 1990
- Quantification techniques for dual‐energy cardiac imagingMedical Physics, 1989
- Scatter‐glare corrections in quantitative dual‐energy fluoroscopyMedical Physics, 1988
- Dual-energy projection radiography: initial clinical experienceAmerican Journal of Roentgenology, 1981
- Real-Time Digital K-Edge Subtraction FluoroscopyInvestigative Radiology, 1979
- Measurement of peak rates of left ventricular wall movement in man. Comparison of echocardiography with angiography.Heart, 1975
- Heart motion video tracking.Heart, 1973
- Calculations of Image Lag in Vidicon-Type Camera Tubes. II Image Lag for Moving Object: Dynamic Image LagJapanese Journal of Applied Physics, 1971