Determination of decimal reduction time (D value) of chemical agents used in hospitals for disinfection purposes
Open Access
- 17 October 2003
- journal article
- research article
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 3 (1) , 24
- https://doi.org/10.1186/1471-2334-3-24
Abstract
Prior to the selection of disinfectants for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common and persistent bacteria identified at a health care facility should be determined. The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension (104 – 105 CFU/mL for vegetative and spore forms). At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. The highest D-values for various bacteria were determined for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0) – E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min) and 0.1% for B. stearothermophilus (D = 3.5 min) and B. subtilis (D = 3.2 min); (iii) 2.0% glutaraldehyde (pH 7.4) – B. stearothermophilus, B. subtilis (D = 25 min) and E. coli (D = 7.1 min); (iv) 0.5% formaldehyde (pH 6.5) – B. subtilis (D = 11.8 min), B. stearothermophilus (D = 10.9 min) and A. calcoaceticus (D = 5.2 min); (v) 2.0% chlorhexidine (pH 6.2) – B. stearothermophilus (D = 9.1 min), and at 0.4% for E. cloacae (D = 8.3 min); (vi) 1.0% Minncare® (peracetic acid and hydrogen peroxide, pH 2.3) – B. stearothermophilus (D = 9.1 min) and E. coli (D = 6.7 min). The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations showed that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasizes the importance and need to develop routine and novel programs to evaluate product utility.Keywords
This publication has 9 references indexed in Scilit:
- Identification of bacteria in drinking and purified water during the monitoring of a typical water purification systemBMC Public Health, 2002
- The efficacy of chemical agents in cleaning and disinfection programsBMC Infectious Diseases, 2001
- Cleaning of Blood-Contaminated Reprocessed Angiographic Catheters and Spinal NeedlesInfection Control & Hospital Epidemiology, 2000
- Antiseptics and Disinfectants: Activity, Action, and ResistanceClinical Microbiology Reviews, 1999
- Bacillus stearothermophilus sporulation response to different composition media.1998
- Inactivation of Brazilian wild type and enterotoxigenicEscherichia coli by chlorineJournal of Industrial Microbiology & Biotechnology, 1996
- APIC guidelines for handwashing and hand antisepsis in health care settingsAmerican Journal of Infection Control, 1995
- FDA Labeling Requirements for Disinfection of Endoscopes: A CounterpointInfection Control & Hospital Epidemiology, 1995
- FDA Labeling Requirements for Disinfection of Endoscopes: A CounterpointInfection Control & Hospital Epidemiology, 1995