Reprocessing of flexible endoscopes
- 1 October 2000
- journal article
- review article
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 15 (s3) , G73-G77
- https://doi.org/10.1046/j.1440-1746.2000.02269.x
Abstract
Proper reprocessing of endoscopes prevents the risk of transmission of infection between patients. Meticulous mechanical cleaning is the most important step as it removes the majority of the contaminating bacteria. It should be performed before manual or automatic disinfection. High‐level disinfection involves total immersion of the endoscope in a liquid chemical germicide (LCG) at a preset temperature and concentration for a pre‐determined period of time. Subsequent rinsing and drying are essential steps to remove the chemical solution and prevent bacterial colonization during storage. Endoscopy units that are used for more than 50 procedures per week may benefit from cleaning in an automatic endoscope reprocessor (AER). This allows automated exposure of the endoscope to the LCG with subsequent flushing and drying of the channels, and minimizes staff exposure to the LCG. Reprocessing should be performed by trained and accredited personnel according to written guidelines or standards of practice as defined by professional societies. Regular monitoring of the reprocessing process is important for quality control and in ensuring patients' safety.Keywords
This publication has 27 references indexed in Scilit:
- Technology Status Evaluation Report: Automatic Endoscope Reprocessors: FEBRUARY 1999Gastrointestinal Endoscopy, 1999
- Technology Status Evaluation: Sheathed Endoscopes: November 1998Gastrointestinal Endoscopy, 1999
- Efficiency and productivity of a sheathed fiberoptic sigmoidoscope compared with a conventional sigmoidoscopeDiseases of the Colon & Rectum, 1997
- Mycobacteria and glutaraldehyde: is high-level disinfection of endoscopes possible?Gastrointestinal Endoscopy, 1996
- Reprocessing of flexible gastrointestinal endoscopesGastrointestinal Endoscopy, 1996
- FDA Labeling Requirements for Disinfection of Endoscopes: A CounterpointInfection Control & Hospital Epidemiology, 1995
- Evaluation of the Steris System 1 peracetic acid endoscope processorJournal of Hospital Infection, 1995
- Proposed Recommended Practices for Chemical DisinfectionAORN Journal, 1994
- Transmission Of Infection By Gastrointestinal EndoscopyGastrointestinal Endoscopy, 1993
- Infection Control Practices in Gastrointestinal Endoscopy in the United States: A National SurveyInfection Control & Hospital Epidemiology, 1991