Do Electrode and Lead Design Differences for Permanent Cardiac Pacing Translate into Clinically Demonstrable Differences? (Comparison of Sintered Platinum and Activated Vitreous and Porous Carbon Electrodes)
- 1 August 1989
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 12 (8) , 1419-1425
- https://doi.org/10.1111/j.1540-8159.1989.tb05057.x
Abstract
A randomized prospective study was undertaken to compare the electrical performances of three permanent, endocardial, tined pacing leads with different electrode designs--sintered platinum, vitreous carbon, and porous carbon. Ninety-nine patients received one of the leads (S80 31; 423S 32; S100 36). Acute R wave amplitude and ST elevation of the native endocardial electrogram, voltage threshold, impedance, and current flow at four pulse durations (0.25-1.0 msec) were measured. Voltage thresholds were measured noninvasively at each of four pulse durations at 2 days and 1, 3, and 6 months after implantation. No significant differences were found in sensing properties, or current flow at threshold at 0.5 msec pulse duration. The 423S lead had a significantly higher impedance at threshold and both a higher impedance and lower current flow at 5 V. No significant differences in threshold voltages were found between the three leads at any pulse duration, at any of the assessed times after implantation. Six-month thresholds for the S80, 423S, and S100 leads were 1.18 +/- 0.35, 1.17 +/- 0.29, and 1.06 +/- 0.38 V respectively at 0.5 msec pulse duration. Differences between 'high performance' pacing leads need to be of a greater order of magnitude before they can be exploited to give any real clinical advantage to patients.Keywords
This publication has 15 references indexed in Scilit:
- Minimum energy for cardiac pacingClinical Physics and Physiological Measurement, 1988
- Clinical Results of Low Energy Unipolar or Bipolar Activated Carbon Tip LeadsPacing and Clinical Electrophysiology, 1986
- Electrochemical Properties of Platinum, Glassy Carbon, and Pyrographite as Stimulating ElectrodesPacing and Clinical Electrophysiology, 1986
- Development of Glassy Carbon Electrode (Dead Sea Scroll) for Low Energy Cardiac PacingPacing and Clinical Electrophysiology, 1986
- Long‐Term Performance of Endocardial Leads with Steroid‐Eluting ElectrodesPacing and Clinical Electrophysiology, 1986
- Target Lead—Low Threshold ElectrodePacing and Clinical Electrophysiology, 1986
- Characterization of chronically implanted ventricular endocardial pacing leadsAmerican Heart Journal, 1984
- The Carbon Tip ElectrodePacing and Clinical Electrophysiology, 1983
- Electrode‐Heart Interface: Definition of the Ideal ElectrodePacing and Clinical Electrophysiology, 1983
- Polarization Properties of Small‐Surface‐Area Pacemaker Electrodes—Implications on Reliability of Sensing arid Pacing*Pacing and Clinical Electrophysiology, 1979