Polarization Properties of Small‐Surface‐Area Pacemaker Electrodes—Implications on Reliability of Sensing arid Pacing*
- 1 July 1979
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 2 (4) , 403-416
- https://doi.org/10.1111/j.1540-8159.1979.tb05216.x
Abstract
The polarization characteristics of Pt-Ir and Elgiloy small-surface-area (10-12.5 mm2) pacemaker electrodes were studied at AC linear (sensing) and DC non-linear (pacing) conditions. The electrodes' AC polarization impedance was approximately equal to the demand pacemaker's input impedance, which causes waveform distortions ofthe sensed R-wave potentials. The pacemaker's coupling capacitor adds to the distortion's effect. As a result of amplitude attenuation (up to approximately 50%) and slew rate changes, the pacemaker may fail to recognize the ventricular complexes, reverting to hazardous competitive pacing. The impact of the DC polarization elements and of the coupling capacitor on the effectiveness of pacing was examined. The deficiency of small area electrodes was pointed out, this being counter-balanced to some extent by their lower pacing thresholds. The necessity to ensure a sufficient safety margin between the pacing pulse and the stimulation threshold, to avoid possible reasons for creation of exit blocks, was stressed. In reducing the electrode surface, it is advisable not to step down below a 15-20 mm2 effective area for Pt-Ir, and a 40-50 mm2 area for Elgiloy.Keywords
This publication has 19 references indexed in Scilit:
- Characteristics of Intracardiac Electrograms*Pacing and Clinical Electrophysiology, 1978
- Influence of Output Capacitor, Electrode and Pulse Width on Power Consumption in Cardiac Pacing‡Pacing and Clinical Electrophysiology, 1978
- Cardiac pacing and pacemakers III. Sensing the cardiac electrogramAmerican Heart Journal, 1977
- Low Threshold Endocardial Electrodes for Permanent Cardiac PacingActa Medica Scandinavica, 1977
- Failure of demand pacing with small surface area electrodes.Circulation, 1976
- Failure of demand pacemaker from low-voltage bipolar ventricular electrogramsPublished by American Medical Association (AMA) ,1971
- POLARIZATION PHENOMENA RELATING TO PHYSIOLOGICAL ELECTRODESAnnals of the New York Academy of Sciences, 1969
- LOW INTRACARDIAC POTENTIALS IN MYOCARDIAL INFARCTION AS A CAUSE OF FAILURE OF INHIBITION OF DEMAND PACEMAKERSThe Lancet, 1968
- MYOCARDIAL AND ENDOCARDIAC ELECTRODES FOR CHRONIC IMPLANTATIONAnnals of the New York Academy of Sciences, 1968
- Alternating current electrode polarizationRadiation and Environmental Biophysics, 1966