Variabilities in measurement of coronary arterial dimensions resulting from variations in cineframe selection
- 1 January 1988
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 14 (4) , 221-228
- https://doi.org/10.1002/ccd.1810140402
Abstract
To quantitatively analyze a coronary arterial segment from a cineangiogram, an enddiastolic or neighboring cineframe is usually selected, such that a possibly existing coronary lesion is visualized optimally, as judged by the cardiologist. However, different cardiologists may select different (although usually neighboring) frames, even when following the same selection criteria. It is also possible that the frames are selected from different cardiac cycles. In this study the effects of such phase shifts on the reproducibility of the quantitative measurements were studied. In a total of 38 consecutive patient films obtained at a filmspeed of 25 frames/sec, the frame O demonstrating the severity of a lesion optimally, as judged by a senior cardiologist, the three preceding frames, the three following frames and one frame exactly one cycle prior to or following frame O were selected; frame O was always chosen in the end‐diastolic phase of the cardiac cycle. In each film one coronary arterial segment with a focal lesion was analyzed quantitatively in these eight frames with the Cardiovascular Angiography Analysis System (CAAS). No significant differences were found in the mean difference and the standard deviations of the differences (variabilities) in the obstruction diameter, interpolated reference diameter, percent diameter stenosis, extent of the obstruction and area of atherosclerotic plaque obtained in the various frames with respect to frame O. Therefore, it may be concluded that the selection of a cineframe for quantitative analysis in the end‐diastolic phase of the cardiac cycle is not very critical; in other words, the obstruction measurements are not time‐dependent for frames in the end‐diastolic phase. It is argued that the quality of mixing of the contrast agent in the arterial segment is a major source of the observed variations; filling artefacts are potentially present in each of the selected frames.Keywords
This publication has 13 references indexed in Scilit:
- Approaches towards standardization in acquisition and quantitation of arterial dimensions from cineangiogramsPublished by Springer Nature ,1986
- A second look at quantitative coronary angiography: some unexpected problemsPublished by Springer Nature ,1986
- Quantitation of coronary artery stenosis severity: Limitations of angiography and computerized information extractionPublished by Springer Nature ,1986
- Diet, Lipoproteins, and the Progression of Coronary AtherosclerosisNew England Journal of Medicine, 1985
- Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution thallium scintigraphyThe American Journal of Cardiology, 1985
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Assessment of dimensions and image quality of coronary contrast catheters from cineangiogramsCatheterization and Cardiovascular Diagnosis, 1985
- Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurementsThe American Journal of Cardiology, 1984
- Influence of intracoronary nifedipine on left ventricular function, coronary vasomotility, and myocardial oxygen consumption.Heart, 1983
- Progression to Complete Coronary Obstruction Without Myocardial Infarction in Patients Who Are Candidates for Percutaneous Transluminal Angioplasty: A 90-Day Angiographic Follow-UpPublished by Springer Nature ,1983