Catheter Ablation for Paroxysmal Atrial Fibrillation: A Randomized Comparison between Multielectrode Catheter and Point-by-Point Ablation
- 1 September 2010
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (9) , 1039-1046
- https://doi.org/10.1111/j.1540-8159.2010.02807.x
Abstract
Catheter ablation for paroxysmal atrial fibrillation is widely used for patients with drug-refractory paroxysms of arrhythmia. Recently, novel technologies have been introduced to the market that aim to simplify and shorten the procedure. To compare the clinical outcome of pulmonary vein (PV) isolation using a multipolar circular ablation catheter (PVAC group), with point-by-point PV isolation using an irrigated-tip ablation catheter and the CARTO mapping system (CARTO group; CARTO, Biosense Webster, Diamond Bar, CA, USA). Patients with documented PAF were randomized to undergo PV isolation using PVAC or CARTO. Atrial fibrillation (AF) recurrences were documented by serial 7-day Holter monitoring. One hundred and two patients (mean age 58 ± 11 years, 68 men) were included in the study. The patients had comparable baseline clinical characteristics, including left atrial dimensions and left ventricular ejection fraction, in both study arms (PVAC: n = 51 and CARTO: n = 51). Total procedural and fluoroscopic times were significantly shorter in the PVAC group (107 ± 31 minutes vs 208 ± 46 minutes, P < 0.0001 and 16 ± 5 minutes vs 28 ± 8 minutes, P < 0.0001, respectively). The AF recurrence was documented in 23% and 29% of patients in the PVAC and CARTO groups, respectively (P = 0.8), during the mean follow-up of 200 ± 13 days. No serious complications were noted in both study groups. Clinical success rates of PV isolation are similar when using multipolar circular PV ablation catheter and point-by-point ablation with a three-dimensional (3D) navigation system in patients with PAF, and results in shorter procedural and fluoroscopic times with a comparable safety profile.Keywords
This publication has 16 references indexed in Scilit:
- Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical resultsJournal of Interventional Cardiac Electrophysiology, 2009
- Anatomical analysis of recurrent conduction after circumferential ablationJournal of Interventional Cardiac Electrophysiology, 2009
- Safe and Rapid Isolation of Pulmonary Veins Using a Novel Circular Ablation Catheter and Duty‐Cycled RF GeneratorJournal of Cardiovascular Electrophysiology, 2009
- Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheterHeart Rhythm, 2008
- Long‐Term Safety and Efficacy of Circumferential Ablation with Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2006
- Atrial Fibrillation Ablation: Reaching the MainstreamPacing and Clinical Electrophysiology, 2006
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Feasibility and Safety of Pulmonary Vein Isolation Using a New Mapping and Navigation System in Patients With Refractory Atrial FibrillationCirculation, 2003
- Catheter Ablation for Paroxysmal Atrial FibrillationCirculation, 2003
- Circumferential Radiofrequency Ablation of Pulmonary Vein OstiaCirculation, 2000