High-speed three-dimensional X-ray computed tomography: The dynamic spatial reconstructor
- 1 March 1983
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 71 (3) , 308-319
- https://doi.org/10.1109/proc.1983.12589
Abstract
Most X-ray CT scanners require a few seconds to produce a single two-dimensional (2-D) image of a cross section of the body. The accuracy of full three-dimensional (3-D) images of the body synthesized from a contiguous set of 2-D images produced by sequential CT scanning of adjacent body slices is limited by 1) slice-to-slice registration (positioning of patient); 2) slice thickness; and 3) motion, both voluntary and involuntary, which occurs during the total time required to scan all slices. Therefore, this method is inadequate for true dynamic 3-D imaging of moving organs like the heart, lungs, and circulation. To circumvent these problems, the Dynamic Spatial Reconstructor (DSR) was designed by the Biodynamics Research Unit at the Mayo Clinic to provide synchronous volume imaging, that is stop-action (1/100 s), high-repetition rate (up to 60/s), simultaneous scanning of many parallel thin cross sections (up to 240, each 0.45 mm thick, 0.9 mm apart) spanning the entire anatomic extent of the bodily organ(s)of interest. These capabilities are achieved by using multiple X-ray sources and multiple 2-D fluoroscopic video camera assemblies on a continually rotating gantry. Desired tradeoffs between temporal, spatial, and density resolution can be achieved by retrospective selection and processing of appropriate subsets of the total data recorded during a continuous DSR scan sequence.Keywords
This publication has 30 references indexed in Scilit:
- Three-Dimensional Spatial, Density, and Temporal Resolution of the Dynamic Spatial ReconstructorJournal of Computer Assisted Tomography, 1982
- Cardiovascular anatomy and function imaging with the dsr in humans with complex congenital heart disease — Initial resultsThe American Journal of Cardiology, 1982
- Technical Aspects and Clinical Applications of CT/X, a Dynamic CT ScannerJournal of Computer Assisted Tomography, 1981
- Evaluation of ischemic heart disease with a prototype volume imaging computed tomographic (CT) scanner: Preliminary experimentsThe American Journal of Cardiology, 1980
- Early Two-Dimensional Reconstruction (CT Scanning) and Recent Topics Stemming from ItJournal of Computer Assisted Tomography, 1980
- Dynamic Computed Tomography of the LungJournal of Computer Assisted Tomography, 1979
- Display and Visualization of Three-Dimensional Reconstructed Anatomic MorphologyJournal of Computer Assisted Tomography, 1979
- QUANTITATIVE IMAGING OF THE STRUCTURE AND FUNCTION OF THE HEART, LUNGS, AND CIRCULATIONJournal of Computer Assisted Tomography, 1979
- Gated Computed Tomography of the Human HeartInvestigative Radiology, 1977
- The shape and movements of the human left ventricle during systoleThe American Journal of Cardiology, 1970