B0 and B1‐insensitive uniform T1‐weighting for quantitative, first‐pass myocardial perfusion magnetic resonance imaging
- 27 October 2005
- journal article
- clinical trial
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (6) , 1423-1429
- https://doi.org/10.1002/mrm.20704
Abstract
Myocardial perfusion can be estimated, in principle, from first‐pass MR images by converting the T1‐weighted signal–time curves to contrast agent concentration–time curves. Typically, T1 weighting is achieved by saturating the magnetization with a nonselective radiofrequency (RF) pulse prior to the imaging sequence. The accuracy of the perfusion estimate derived from the single‐point T1‐weighted signal depends on the initial residual longitudinal magnetization (RLM) produced by the saturation pulse. In this study we demonstrate that single‐shot, echo‐planar imaging can be used to show initial RLM resulting from incomplete saturation due to static magnetic field and RF field inhomogeneities in the heart at 1.5 T. Three saturation pulses, single, composite simple, and composite B1‐insensitive rotation (BIR‐4) were evaluated in phantom and cardiac experiments. The RLM image was calculated by normalizing the saturated image by a proton‐density‐weighted image. Mean RLM produced by the three saturation pulses was significantly different in noncontrast cardiac imaging (RLMsingle = 0.108 ± 0.078; RLMcomposite = 0.051 ± 0.052; RLMBIR‐4 = 0.011 ± 0.009; P < 0.001; n = 20). Using a BIR‐4 pulse to perform saturation of magnetization seems promising for improving the effectiveness and uniformity of T1 weighting for first‐pass perfusion imaging. Magn Reson Med, 2005.Keywords
This publication has 20 references indexed in Scilit:
- Magnetic resonance imaging of myocardial contrast enhancement with MS‐325 and its relation to myocardial blood flow and the perfusion reserveJournal of Magnetic Resonance Imaging, 2003
- Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0TJournal of Magnetic Resonance Imaging, 2003
- Imaging of the active B1 field in vivoMagnetic Resonance in Medicine, 1996
- Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparationMagnetic Resonance in Medicine, 1995
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- Effect of Radio Frequency Inhomogeneity Correction on the Reproducibility of Intra‐Cranial Volumes Using MR Image DataMagnetic Resonance in Medicine, 1995
- Sources of intensity nonuniformity in spin echo images at 1.5 TMagnetic Resonance in Medicine, 1994
- Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRIIEEE Transactions on Medical Imaging, 1993
- 3-D FLASH Imaging Using a Single Surface Coil and a New Adiabatic Pulse, BIR-4Investigative Radiology, 1990
- NMR population inversion using a composite pulseJournal of Magnetic Resonance (1969), 1979