Estimating energy expenditure using accelerometers
Top Cited Papers
- 21 October 2006
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 98 (6) , 601-612
- https://doi.org/10.1007/s00421-006-0307-5
Abstract
The purpose of this study was to examine the validity of published regression equations designed to predict energy expenditure (EE) from accelerometers (Actigraph, Actical, and AMP-331) compared to indirect calorimetry, over a wide range of activities. Forty-eight participants (age: 35 ± 11.4 years) performed various activities that ranged from sedentary behaviors (lying, sitting) to vigorous exercise. The activities were split into three routines of six activities, and each participant performed at least one routine. The participants wore three devices (Actigraph, Actical, and AMP-331) and simultaneously, EE was measured with a portable metabolic system. For the Actigraph, 15 previously published equations were used to estimate EE from the accelerometer counts. For the Actical, two published equations were used to estimate EE from the accelerometer counts. For the AMP-331 we used the manufacturer’s equation to estimate EE. The Actigraph and Actical regressions tended to overestimate walking and sedentary activities and underestimate most other activities. The AMP-331 gave a close estimate of EE during walking, but overestimated sedentary/light activities and underestimated all other activities. The only equation not significantly different from actual time spent in both light and moderate physical activity was the Actigraph Freedson kcal equation. All equations significantly underestimated time spent in vigorous physical activity (P < 0.05). In conclusion, no single regression equation works well across a wide range of activities for the prediction of EE or time spent in light, moderate, and vigorous physical activity.Keywords
This publication has 25 references indexed in Scilit:
- A novel method for using accelerometer data to predict energy expenditureJournal of Applied Physiology, 2006
- Predicting Activity Energy Expenditure Using the Actical® Activity MonitorResearch Quarterly for Exercise and Sport, 2006
- Novel Technique for Assessing Physical Activity Using Accelerometer DataMedicine & Science in Sports & Exercise, 2004
- Accuracy of a New Activity Monitor for Assessing Exercise Intensity during WalkingMedicine & Science in Sports & Exercise, 2004
- Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical ActivityInternational Journal of Sports Medicine, 2003
- Ability of Different Physical Activity Monitors to Detect Movement During Treadmill WalkingInternational Journal of Sports Medicine, 2003
- Validation of the COSMED K4 b2 Portable Metabolic SystemInternational Journal of Sports Medicine, 2001
- Comparisons of four methods of estimating physical activity in adult womenMedicine & Science in Sports & Exercise, 2000
- Assessment of Physical Activity with the Computer Science and Applications, Inc., Accelerometer: Laboratory versus Field ValidationResearch Quarterly for Exercise and Sport, 2000
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986