A novel method for using accelerometer data to predict energy expenditure
Top Cited Papers
- 1 April 2006
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 100 (4) , 1324-1331
- https://doi.org/10.1152/japplphysiol.00818.2005
Abstract
The purpose of this study was to develop a new two-regression model relating Actigraph activity counts to energy expenditure over a wide range of physical activities. Forty-eight participants [age 35 yr (11.4)] performed various activities chosen to represent sedentary, light, moderate, and vigorous intensities. Eighteen activities were split into three routines with each routine being performed by 20 individuals, for a total of 60 tests. Forty-five tests were randomly selected for the development of the new equation, and 15 tests were used to cross-validate the new equation and compare it against already existing equations. During each routine, the participant wore an Actigraph accelerometer on the hip, and oxygen consumption was simultaneously measured by a portable metabolic system. For each activity, the coefficient of variation (CV) for the counts per 10 s was calculated to determine whether the activity was walking/running or some other activity. If the CV was ≤10, then a walk/run regression equation was used, whereas if the CV was >10, a lifestyle/leisure time physical activity regression was used. In the cross-validation group, the mean estimates using the new algorithm (2-regression model with an inactivity threshold) were within 0.75 metabolic equivalents (METs) of measured METs for each of the activities performed ( P ≥ 0.05), which was a substantial improvement over the single-regression models. The new algorithm is more accurate for the prediction of energy expenditure than currently published regression equations using the Actigraph accelerometer.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of Activity Monitors to Estimate Energy Cost of Treadmill ExerciseMedicine & Science in Sports & Exercise, 2004
- Reexamination of Validity and Reliability of the CSA Monitor in Walking and RunningMedicine & Science in Sports & Exercise, 2003
- Ability of Different Physical Activity Monitors to Detect Movement During Treadmill WalkingInternational Journal of Sports Medicine, 2003
- Validation of the COSMED K4 b2 Portable Metabolic SystemInternational Journal of Sports Medicine, 2001
- Validity of accelerometry for the assessment of moderate intensity physical activity in the fieldMedicine & Science in Sports & Exercise, 2000
- Validity of four motion sensors in measuring moderate intensity physical activityMedicine & Science in Sports & Exercise, 2000
- Physical Activity and Coronary Heart Disease Risk in MenCirculation, 2000
- Calibration of the Computer Science and Applications, Inc. accelerometerMedicine & Science in Sports & Exercise, 1998
- Changes in Physical Fitness and All-Cause MortalityJAMA, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986