Influence of Local Environment on Incorporation of Ceramic for Lumbar Fusion
- 1 August 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 22 (15) , 1683-1689
- https://doi.org/10.1097/00007632-199708010-00001
Abstract
Previous comparative studies have assessed that the efficacy of bone graft substitutes for spine fusion depends on their physicochemical properties and on the mechanical environment, but rarely on the grafting site at the lumbar spine level. Posterior and lateral arthrodesis using pedicular instrumentation was performed at L2, L3, and L4 with a parallelepipedic ceramic block in an experimental group of dogs. A second group of dogs was fused with only autogenous bone graft to compare the fusion stiffness obtained with this material with the stiffness obtained with ceramic. Dogs were studied for 9 months. A biomechanical test and histomorphometric analysis were conducted. With the biomechanical test, no significant differences were found between ceramic and autogenous bone. The percentage of newly formed bone was higher (P < 0.0001) at the lamina (26.52 ± 6.45%) than at the transverse process site (17.33 ± 2.54%). For both locations, the highest amount of newly formed bone was observed in the area of close contact between ceramic and bone, and the lowest was observed in central areas (24.6 ± 5.9% for the laminar site, 14.79 ± 1.75% for the transverse process site). This animal study, which replicated the human procedure in posterolateral lumbar fusion, showed a significant difference of ceramic incorporation between laminar and intertransverse sites. This histomorphometric analysis also confirmed the relationship between bone in-growth and ceramic thickness and ceramic contact area with bone.Keywords
This publication has 28 references indexed in Scilit:
- Experimental Spinal Fusion With Recombinant Human Bone Morphogenetic Protein-2Spine, 1995
- Mechanical changes in macro-porous calcium phosphate ceramics after implantation in boneClinical Materials, 1994
- Experimental Model of Posterolateral Spinal Arthrodesis in SheepSpine, 1994
- A Paradigm of Delayed Union and Nonunion in the Lumbosacral JointSpine, 1991
- Macroporous Calcium Phosphate Ceramic Performance in Human Spine FusionPublished by Wolters Kluwer Health ,1989
- Morbidity at Bone Graft Donor SitesJournal of Orthopaedic Trauma, 1989
- Response of Bone Marrow Stroma Cells to Demineralized Cortical Bone Matrix in Experimental Spinal Fusion in RabbitsPublished by Wolters Kluwer Health ,1988
- Bone ingrowth into three different porous ceramics implanted into the tibia of rats and rabbitsJournal of Orthopaedic Research, 1985
- Experimental Spinal Fusion with Decalcified Bone Matrix and Deep-frozen Allogeneic Bone in RabbitsClinical Orthopaedics and Related Research, 1982
- Experimental Spinal Fusion in Guinea Pigs and Dogs The Effect of ImmobilizationClinical Orthopaedics and Related Research, 1975