Achieved Versus Intended Pulse Oximeter Saturation in Infants Born Less Than 28 Weeks' Gestation: The AVIOx Study
- 1 October 2006
- journal article
- research article
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 118 (4) , 1574-1582
- https://doi.org/10.1542/peds.2005-0413
Abstract
OBJECTIVE. The objective of this study was to document pulse oximeter saturation levels achieved in the first 4 weeks of life in infants who were born at <28 weeks' gestation, compared with the levels that were targeted by local policy, and examine factors that are associated with compliance with the target range. METHODS. Infants who were <28 weeks' gestation and ≤96 hours of age were enrolled in a prospective, multicenter cohort study. Oximetry data were collected with masked signal-extraction oximeters for a 72-hour period in each of the first 4 weeks of life. Data were compared with the pulse oximeter saturation target range prescribed by local institutional policy. Factors that were associated with intended range compliance were identified with hierarchical modeling. RESULTS. Fourteen centers from 3 countries enrolled 84 infants with mean ± SD birth weight of 863 ± 208 g and gestational age of 26 ± 1.4 weeks. Oxygen saturation policy limits ranged between 83% and 92% for lower limits and 92% and 98% for upper limits. For infants who received respiratory support, median pulse oximeter saturation level achieved was 95%. Center-specific medial levels were within the intended range at 12 centers. Centers maintained infants within their intended range 16% to 64% of the time but were above range 20% to 73% of the time. In hierarchical modeling, wider target ranges, higher target range upper limits, presence of a policy of setting oximeter alarms close to the target range limits, and lower gestational age were associated with improved target range compliance. CONCLUSIONS. Success with maintaining the intended pulse oximeter saturation range varied substantially among centers, among patients within centers, and for individual patients over time. Most noncompliance was above the intended range. Methods for improving compliance and the effect of improved compliance on neonatal outcomes require additional research.Keywords
This publication has 20 references indexed in Scilit:
- Predicting Risk-Adjusted Mortality for CABG SurgeryMedical Care, 2005
- A Pulmonary Score for Assessing the Severity of Neonatal Chronic Lung DiseasePediatrics, 2005
- Automatic Control of the Inspired Oxygen Fraction in Preterm InfantsAmerican Journal of Respiratory and Critical Care Medicine, 2004
- Latin American Society for Paediatric Research (LASPR) Selected Abstracts from the XLI Annual Meeting October 2003 – Marbella, Chile President: Fernando Pizarro (Chile) President Elect: José Tantalean (Perú) General Secretary: Luis Guimarey (Argentina)Pediatric Research, 2004
- Oxygen-Saturation Targets and Outcomes in Extremely Preterm InfantsNew England Journal of Medicine, 2003
- Detection of hyperoxaemia in neonates: data from three new pulse oximetersArchives of Disease in Childhood: Fetal & Neonatal, 2002
- A Comparison of Three Doses of a Commercially Prepared Oral Midazolam Syrup in ChildrenAnesthesia & Analgesia, 2002
- Pulse oximetry, severe retinopathy, and outcome at one year in babies of less than 28 weeks gestationArchives of Disease in Childhood: Fetal & Neonatal, 2001
- Do Clinical Markers of Barotrauma and Oxygen Toxicity Explain Interhospital Variation in Rates of Chronic Lung Disease?Pediatrics, 2000
- Supplemental Therapeutic Oxygen for Prethreshold Retinopathy of Prematurity (STOP-ROP), A Randomized, Controlled Trial. I: Primary OutcomesPediatrics, 2000