To compare work of breathing and breathing asynchrony during bubble nasal continuous positive airway pressure (NCPAP) vs variable-flow (VF)-NCPAP in premature infants. We studied 18 premature infants of birth weight <1500 g who required NCPAP for mild respiratory distress. Each infant was studied on bubble and VF-NCPAP at 8, 6, 4, and 0 cm H2O. Tidal volumes were obtained by calibrated respiratory inductance plethysmography. Esophageal pressure estimated intrapleural pressure. Inspiratory and resistive work of breathing were calculated from pressure-volume data. Breathing asynchrony was assessed with phase angle. The results at all NCPAP levels were referenced to VF-NCPAP values at 8 cm H2O. Provision of NCPAP with either device decreased inspiratory work of breathing, tidal volume, and minute ventilation relative to NCPAP of 0 cm H2O. Bubble NCPAP did not decrease resistive work of breathing relative to 0 cm H2O. Resistive work of breathing (p=0.01), respiratory rate (p<0.03), and phase angle (p=0.002) were all greater with bubble compared to VF-NCPAP. The more labored and asynchronous breathing seen with bubble NCPAP may lead to higher failure rates over the long term than with VF-NCPAP.Keywords
This publication has 16 references indexed in Scilit:
- Glutathione S Transferase Theta 1 Gene (GSTT1) Null Genotype Is Associated with an Increased Risk for Acquired Aplastic Anemia in ChildrenPediatric Research, 2004
- A Randomized, Controlled Trial Comparing Two Different Continuous Positive Airway Pressure Systems for the Successful Extubation of Extremely Low Birth Weight InfantsPediatrics, 2003
- Changes in lung volume and work of breathing: A comparison of two variable‐flow nasal continuous positive airway pressure devices in very low birth weight infantsPediatric Pulmonology, 2003
- Devices and pressure sources for administration of nasal continuous positive airway pressure (NCPAP) in preterm neonatesPublished by Wiley ,2002
- Early versus delayed initiation of continuous distending pressure for respiratory distress syndrome in preterm infantsCochrane Database of Systematic Reviews, 2002
- Lung injury in neonates: Causes, strategies for prevention, and long-term consequencesThe Journal of Pediatrics, 2001
- A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infantsArchives of Disease in Childhood: Fetal & Neonatal, 2001
- Bronchopulmonary DysplasiaAmerican Journal of Respiratory and Critical Care Medicine, 2001
- A new device for administration of nasal continuous positive airway pressure in the newbornCritical Care Medicine, 1988
- Treatment of the Idiopathic Respiratory-Distress Syndrome with Continuous Positive Airway PressureNew England Journal of Medicine, 1971