Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
Open Access
- 1 January 1999
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 70 (6) , 578-582
- https://doi.org/10.3109/17453679908997845
Abstract
Aseptic loosening due to osteolysis in total hip replacement has been related to wear debris released from prosthetic components. Retrospective long-term observations of patients with the metal-on-metal prosthesis has shown long-term survivorship and good mechanical performance. Thus, the new and modified metal-on-metal prosthesis has been introduced on the market. Historical clinical data from the 1 st generation metal-on-metal hip prosthesis may not be relevant for the 2nd generation of metal-on-metal hip prosthesis. Therefore, preclinical testing of the prosthesis must be conducted before clinical evaluation. We assessed the tribological performance of the metal-on-metal prosthesis versus the metal-on-polyethylene prosthesis introduced on the market as Metasul™ and Protasul™, respectively. In a 12-channel joint simulator, 6 metal-on-metal bearing and 3 metal on polyethylene prostheses were tested, with the same number of corresponding soak controls. The wear was assessed gravimetrically. The “steady-state” wear-rates from the metal-on-metal prosthesis were almost 100 times less than that from the metal-on-polyethylene prosthesis. The tribological wear performance of the metal-on-metal hip prosthetic system is promising.Keywords
This publication has 17 references indexed in Scilit:
- Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996
- Metal on Metal BearingsPublished by Wolters Kluwer Health ,1996
- Metal on Metal Bearings in Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal ImplantsClinical Orthopaedics and Related Research, 1996
- Experience With the Metasul Total Hip Bearing SystemClinical Orthopaedics and Related Research, 1996
- Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfacesThe Journal of Arthroplasty, 1996
- Total hip arthroplasty with Boneloc®:Loosening in 102/157 cases after 0.5–3 yearsActa Orthopaedica, 1996
- Hip-simulator ranking of polyethylene wear:Comparisons between ceramic heads of different sizesActa Orthopaedica, 1996
- Failure of the Christiansen hip: Survival analysis of 265 casesActa Orthopaedica, 1990
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977