Sterile radial artery granuloma after transradial procedures
- 25 October 2010
- journal article
- review article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 76 (5) , 673-676
- https://doi.org/10.1002/ccd.22730
Abstract
Trans‐radial cardiac catheterization has lower rates of arterial access site complications. Hydrophilic‐coated sheaths designed specifically for trans‐radial procedures have resulted in numerous reports of a foreign body reaction to retained material. Although this is a self‐limited condition that should be managed expectantly, it is often confused with an infected pseudoaneurysm, resulting in unnecessary surgery. We searched the FDA MAUDE (Manufacturer and User Facility Device Experience) database to determine which brands of sheath have been associated with this complication. In addition, we performed a literature search for all reported cases of this complication. Only one brand of sheath has been associated with this condition. As trans‐radial procedures become more common in the US, knowledge of such complications, which appear to be specific to the Cook radial hydrophilic‐coated sheaths, is imperative for all radial interventionalists to prevent unnecessary surgical procedures.Keywords
This publication has 13 references indexed in Scilit:
- Sterile granuloma formation following radial artery catheterization: Too many Cooks?Catheterization and Cardiovascular Interventions, 2010
- Hydrophilic-Coated Radial SheathsJACC: Cardiovascular Interventions, 2010
- Sterile granuloma formation following radial artery facilitated coronary catheterizationCatheterization and Cardiovascular Interventions, 2009
- Sterile abscess formation as a complication of hydrophilic radial artery cannulationInternational Journal of Cardiology, 2008
- Association of the arterial access site at angioplasty with transfusion and mortality: the M.O.R.T.A.L study (Mortality benefit Of Reduced Transfusion after percutaneous coronary intervention via the Arm or Leg)Heart, 2008
- Sterile inflammation after transradial catheterization using a hydrophilic sheath: a case reportInternational Journal of Cardiology, 2005
- Nonhealing wound resulting from a foreign body to a radial arterial sheath and sterile inflammation associated with transradial catheterization and hydrophilic sheathsCatheterization and Cardiovascular Interventions, 2004
- Sterile inflammation associated with transradial catheterization and hydrophilic sheathsCatheterization and Cardiovascular Interventions, 2003
- Nonhealing wound resulting from a foreign‐body reaction to a radial arterial sheathCatheterization and Cardiovascular Interventions, 2003
- Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double‐blind comparison of coated and uncoated sheathsCatheterization and Cardiovascular Interventions, 2003