Verification of total body photon irradiation dosimetry techniques
- 1 May 1988
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 15 (3) , 364-369
- https://doi.org/10.1118/1.596232
Abstract
A method of verifying the dosimetry of patients undergoing total body irradiation (TBI) with photon beams having energies from cobalt-60 to 25 MV is presented. A simple set of spot checks at the TBI axis has been used to verify data used for TBI dosimetry. Calculations to verify dose delivered to TBI patients are done in the same manner as those irradiated at standard treatment distances. A simple method of effective field size determination for various anatomical locations in a typical adult is presented. Measurements in an Alderson phantom with thermoluminescent dosimeters and an ion chamber at several anatomical locations indicate that this calculational method can predict the dose along the patient axis to within 4% for 60Co and 18-MV photon beams, provided the dosimetry data are appropriate (as determined by the spot checks). Results of intercomparisons of TBI beam calibration, off-axis and depth-dose data at various institutions visited by the Radiological Physics Center are also presented.Funding Information
- Presbyterian Historical Society (CA 10953)
- National Cancer Institute
- DHHS
This publication has 9 references indexed in Scilit:
- Lung corrections in photon beam treatment planning: are we ready?International Journal of Radiation Oncology*Biology*Physics, 1984
- Total body irradiation with a sweeping beamInternational Journal of Radiation Oncology*Biology*Physics, 1983
- Comparative 60Co total body irradiation (220 cm SAD) and 25 MV total body irradiation (370 cm SAD) dosimetryInternational Journal of Radiation Oncology*Biology*Physics, 1980
- Total body irradiation with a 10 mv linear accelerator in conjunction with bone marrow transplantationInternational Journal of Radiation Oncology*Biology*Physics, 1980
- Calculative technique to correct for the change in linear accelerator beam energy at off-axis pointsMedical Physics, 1980
- Radiobiological Considerations in the Use of Total-Body Irradiation for Bone-Marrow TransplantationRadiology, 1979
- Utilization of a High Energy Photon Beam for Whole Body IrradiationRadiology, 1977
- Total body irradiation utilizing a single 60Co sourceInternational Journal of Radiation Oncology*Biology*Physics, 1976
- A Note on Depth Doses in Fields of Irregular ShapeThe British Journal of Radiology, 1941