Three‐Point Phase‐Contrast Velocity Measurements with Increased Velocity‐to‐Noise Ratio
- 1 January 1995
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 33 (1) , 122-126
- https://doi.org/10.1002/mrm.1910330119
Abstract
We describe a technique to increase the velocity-to-noise ratio (VNR) of phase-contrast magnetic-resonance velocity images based on making three measurements/flow encoding axis rather than the usual two. A phase-aliased high first moment data set and a nonaliased low first moment data set are acquired, and the high-moment data are phase unwrapped using the low-moment data. The VNR of the resulting measurement is given by that of the high-moment measurement and increases linearly with the first moment. A factor of 4 gain in VNR was observed with only a 50% increase in scan time. Thus, this method is a much more efficient way to increase VNR than simple averaging.Keywords
This publication has 6 references indexed in Scilit:
- A weighted least‐squares method for nuclear magnetic resonance velocity imagingMagnetic Resonance in Medicine, 1993
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991
- Flow-velocity imaging from linear regression of phase images with techniques for reducing eddy-current effectsJournal of Magnetic Resonance (1969), 1990
- Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsetsMagnetic Resonance in Medicine, 1990
- Correction of phase wrapping in magnetic resonance imagingMedical Physics, 1989
- NMR blood flow imaging using multiecho, phase contrast sequencesMedical Physics, 1985