Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
- 1 September 1990
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 15 (3) , 420-437
- https://doi.org/10.1002/mrm.1910150308
Abstract
The dynamic range of phase-reconstructed magnetic resonance images is compared to that of magnitude-reconstructed images. From analysis of propagation of errors, the phase angle noise is phase-independent and given in radians by σ (|I|)/|I|, the noise-to-signal ratio of the corresponding magnitude-reconstructed image. As the phase can range from minus π to π the phase angle dynamic range is 2π times that of the signal magnitude. These results agree with experiment, verifying that the noise in the two receiver channels is uncorrelated. An artifact-free technique is presented for correcting phase spillover, which further extends the phase angle dynamic range. The reconstruction-based reference phase is adjusted on a local basis so that the boundary of phase wraparound is reconstructed near the center of the [ − π, π] interval. For a particular flow study, the phase signal-to-noise was extended over twofold by spillover correction, to a value 15 times that of the magnitude signal-to-noise. © 1990 Academic Press, Inc.This publication has 39 references indexed in Scilit:
- Multiecho magnetic resonance angiographyMagnetic Resonance in Medicine, 1987
- The effect of magnetic susceptibility variations in NMR imaging and nmr spectroscopy in vivoJournal of Magnetic Resonance (1969), 1986
- High‐resolution human in vivo spectroscopic imaging using echo‐ time encoding techniqueMagnetic Resonance in Medicine, 1986
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986
- MR Velocity Imaging by Phase DisplayJournal of Computer Assisted Tomography, 1985
- Retrieval of frequencies, amplitudes, damping factors, and phases from time-domain signals using a linear least-squares procedureJournal of Magnetic Resonance (1969), 1985
- Two Computer Models for Selection of Optimal Magnetic Resonance Imaging (MRI) Pulse Sequence TimingInvestigative Radiology, 1984
- Coherence levels and coherence pathways in NMR. A simple way to design phase cycling proceduresJournal of Magnetic Resonance (1969), 1984
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978