Interface gap after implantation of a cemented femoral stem in pigs
Open Access
- 1 January 1999
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 70 (3) , 234-239
- https://doi.org/10.3109/17453679908997799
Abstract
We studied the interface gap around cemented femoral stems. Fresh pig femora were used. Bone cement mixed under vacuum or at atmospheric pressure was injected into the femoral canal and a cobalt chrome stem was then implanted. The femora were sectioned transversely from the minor trochanter and distally by using a high-pressure water cutter. Most of the interfaces had intimate contact. However, in all specimens, small gaps were found at the bone-cement and cement-stem interfaces. The gaps at the interfaces between the bone and cement and the cement and stem were measured, using a computerized video digital system. They occupied about 10% of the circumference at the bone-cement interface and about 15% of the circumference at the cement-stem interface, irrespective of the mixing procedures. Most gaps were less than 100 u at the interfaces. In conclusion, cemented implants in the animal model showed that small gaps are found at the interfaces directly after implantation. These gaps may be weak points and initiate debonding when loading the prostheses.Keywords
This publication has 18 references indexed in Scilit:
- Cement Debonding Process of Total Hip Arthroplasty StemsClinical Orthopaedics and Related Research, 1997
- Comparison of diametral shrinkage of centrifuged and uncentrifuge simplex P® bone cementJournal of Applied Biomaterials, 1995
- Prediction of clinical outcome of THR from migration measurements on standard radiographs. A study of cemented Charnley and Stanmore femoral stemsThe Journal of Bone and Joint Surgery. British volume, 1995
- Mechanical failure of cemented femoral total hip replacementPublished by Springer Nature ,1995
- Theories of wear and loosening in hip prostheses: Wear-induced loosening vs loosening-induced wear–a reviewActa Orthopaedica, 1994
- Porosity of bone cement reduced by mixing and collecting under vacuumActa Orthopaedica, 1993
- Extensive porosity at the cement–femoral prosthesis interface: A preliminary studyJournal of Biomedical Materials Research, 1993
- Early detection of prosthetic-hip loosening: Comparison of low- and high-viscosity bone cementActa Orthopaedica, 1990
- Vacuum mixing of acrylic bone cementThe Journal of Arthroplasty, 1987
- Strength of polymethylmethacrylate increased by vacuum mixingActa Orthopaedica, 1984