Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
- 15 October 1996
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 94 (8) , 1870-1875
- https://doi.org/10.1161/01.cir.94.8.1870
Abstract
Background Pulse wave distortions, mainly caused by reflections, and pressure gradients, caused by flow in the resistive vascular tree, may cause differences between finger and brachial artery pressures. These differences may limit the use of finger pressure measurements. We investigated whether brachial artery pressure waves could be reconstructed from finger pressure measurements by correcting for the pressure gradient in addition to correction for pulse wave distortion with a previously described filter. Methods and Results Finger artery pressure (with Finapres), intra-arterial brachial artery pressure (BAP), Riva-Rocci/Korotkoff (RRK), oscillometric, and return-to-flow (RTF) measurements were simultaneously performed in 57 healthy elderly subjects and patients with vascular disease and/or hypertension. A generalized waveform filter was used to correct for pulse wave distortions. Correction equations for the pressure gradient, based on finger pressure, RRK, RTF, or oscillometric measurements, were obtained in 28 randomly selected subjects and tested in 29. Before reconstruction, Finapres underestimated mean and diastolic BAP (finger pressure minus BAP: systolic, −3.2±16.9 mm Hg; mean, −13.0±10.5 mm Hg; diastolic, −8.4±9.0 mm Hg [mean±SD]). After filtering, reconstructed BAP waves were similar to actual BAP in shape but not in pressure level. Optimal correction for the pressure gradient with an equation based on RTF measurements reduced the pressure differences to meet American Association for the Advancement of Medical Instrumentation criteria (reconstructed finger pressure minus BAP: systolic, 3.7±7.0 mm Hg; mean, 0.7±4.6 mm Hg; and diastolic, 1.0±4.9 mm Hg). Conclusions BAP waves can be reconstructed from noninvasive finger pressure registrations when finger pressure waves are corrected for pulse wave distortion and individual pressure gradients.Keywords
This publication has 21 references indexed in Scilit:
- Effect of Regional and Systemic Changes in Vasomotor Tone on Finger Pressure AmplificationHypertension, 1995
- Aortofemoral transfer function: a method to determine the instantaneous aortic valve gradient in aortic valve stenosisJournal of the American College of Cardiology, 1993
- National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.Hypertension, 1993
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993
- Pseudohypertension and the measurement of blood pressure.Hypertension, 1992
- Continuous finger arterial pressure: Utility in the cardiovascular laboratoryClinical Autonomic Research, 1991
- Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressureCardiovascular Research, 1990
- Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.Hypertension, 1989
- Effects of peripheral vasoconstriction on the measurement of blood pressure in a fingerCardiovascular Research, 1985
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981