Reliability of a New Algorithm for Automatic Mode Switching from DDDR to DDIR Pacing Mode in Sinus Node Disease Patients with Chronotropic Incompetence and Recurrent Paroxysmal Atrial Fibrillation
- 1 November 1996
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 19 (11) , 1719-1723
- https://doi.org/10.1111/j.1540-8159.1996.tb03213.x
Abstract
To evaluate the safety and efficacy of a new algorithm for automatic mode switching (AMS) from DDD‐DDDR to DDIR, 26 patients, 16 females and 10 males, mean age 73 ± 6 years of age, affected by sinus node disease, chronotropic incompetence, and recurrent paroxysmal atrial fibrillation (PAF) received the Medtronic Them DR pacemaker. The device continuously calculates, in ms, the running average of the intrinsic atrial rate (MAR) and compares the current atrial interval (CAI) with the stored MAR. When the CAI is greater than the MAR it increases by 8 ms, and when the CAI is less than the MAR, it decreases by 23 ms. When MAR ± 330 ms (182 beats/mm), tachycardia is detected and AMS is activated. All patients had clinical evaluation, 12‐lead ECG, Holter monitoring, and exercise testing after implantation and every 3 months for 1 year. The results were compared with the data stored in the pacemaker memory: AMS episodes number; the histogram of the last 14 episodes; and atrial electrogram recording. Twenty‐two Holier recordings in 13 patients showed PAF and in all of them AMS occurred simultaneously. AMS lasted between 10 seconds and 20 hours, and MAR ranged from 195–400 beats/mm. No episode of PAF and no AMS were recorded in 39 Holter recordings in 22 patients. Appropriate AMS was confirmed in five patients by stored atrial electrogram and in nine by 12‐lead ECG and pacemaker event markers. Mean atrial sensing was 2.13 ± 1.04 mV during PAF and 3,18 ± 1.46 mV during sinus rhythm. No PAF episode and no AMS were recorded during exercise testing. In conclusion, this new algorithm was very reliable, sensitive, and specific.Keywords
This publication has 10 references indexed in Scilit:
- Comparison of Bipolar Atrial Electrogram Amplitude in Sinus Rhythm, Atrial Fibrillation, and Atrial FlutterPacing and Clinical Electrophysiology, 1996
- Initial Experience with a New Algorithm for Automatic Mode Switching from DDDR to DDIR ModePacing and Clinical Electrophysiology, 1994
- Initial Experience with Mode Switching in a Dual Sensor, Dual Chamher Pacemaker in Patients with Paroxysmal Atrial TachyarrhythmiasPacing and Clinical Electrophysiology, 1994
- A New Automode Switch Algorithm for Supraventricular TachycardiasPacing and Clinical Electrophysiology, 1994
- DDI Pacing: Indications, Expectations, and Follow‐UpPacing and Clinical Electrophysiology, 1994
- Atrial Arrhythmia Management with Sensor Controlled Atrial Refractory Period and Automatic Mode Switching in Patients with Minute Ventilation Sensing Dual Chamber Rate Adaptive PacemakersPacing and Clinical Electrophysiology, 1992
- DDDR PacingPacing and Clinical Electrophysiology, 1990
- Relation of prognosis in sick sinus syndrome to age, conduction defects and modes of permanent cardiac pacingThe American Journal of Cardiology, 1990
- Rate Responsive Cardiac Pacing‐A PerspectivePacing and Clinical Electrophysiology, 1989