Experiences with the Radiochromium method for Determination of Red Cell Volume
- 1 January 1962
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 14 (4) , 355-367
- https://doi.org/10.3109/00365516209079721
Abstract
We have described in detail a modification of Sterling and Gray's Cr51 method for blood volume determination with which we have had considerable experience. The dose of Cr51 needed for tagging 12 ml of the patient's blood need not exceed 50—75 μC if a well-type scintillation counter is used. The tagged cell suspension is usually stored overnight so that the test can he done conveniently before breakfast. The cells are delivered from a small infusion apparatus through an indwelling needle which is also used for sampling. The over-all error of the measurement of cell volume, as shown by repeating the test after intervals of 3 to 31 weeks, averages 3.9 per cent. This compares favorably with results obtained with other modifications of the Cr51 method and with P32, even though the long time interval between tests in this study allowed the possibility of within-subject changes of cell volume. The major sources of error are a) the determination of radioactivity of blood specimens and tagged cell suspension, and b) determination of the centrifuged hematocrit, particularly with respect to the percentage of trapped plasma iii the cell column. Failure to measure accurately the volume of tagged cell suspension delivered to the subject, a serious potential source of error, proved to be relatively unimportant with the technique used. Errors relating to the collection and handling of blood for hematocrit determinations and in the prediction of the “body hematocrit: venous hematrocrit ratio can materially affect the estimation of blood and plasma volumes, but not cell volume.Keywords
This publication has 29 references indexed in Scilit:
- Blood VolumePhysiological Reviews, 1959
- The Loss of Fluid and Protein From the Blood During a Systemic Rise of Venous Pressure Produced by Repeated Valsalva Maneuvers in Man1Journal of Clinical Investigation, 1958
- Mixing of Cr 51 -Labeled Red Cells in Patients with Congestive Heart Failure and ControlsCirculation Research, 1957
- Blood Volume and its RegulationAnnual Review of Physiology, 1957
- The Effect of Congestive Heart Failure on Blood Volume as Determined by Radiochromium-Tagged Red CellsCirculation, 1954
- Precision of red cell volume measurement using32P-labelled cellsThe Journal of Physiology, 1954
- THE BODY/VENOUS HEMATOCRIT RATIO: ITS CONSTANCY OVER A WIDE HEMATOCRIT RANGEJournal of Clinical Investigation, 1953
- The Blood Volume in Various Medical and Surgical ConditionsNew England Journal of Medicine, 1952
- VENOUS CONGESTION OF THE EXTREMITIES IN RELATION TO BLOOD VOLUME DETERMINATIONS AND TO MIXING CURVES OF CARBON MONOXIDE AND T-1824 IN NORMAL HUMAN SUBJECTS 1Journal of Clinical Investigation, 1951
- A Method of Blood Volume DeterminationActa Physiologica Scandinavica, 1940