First experimental results of time-of-flight reconstruction on an LSO PET scanner
- 13 September 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (19) , 4507-4526
- https://doi.org/10.1088/0031-9155/50/19/006
Abstract
Time-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been implemented in the CPS Hi-Rez PET scanner, both with 2D filtered-back-projection (FBP2D) and 3D ordered subset expectation maximization (OSEM3D). A new procedure has been introduced in the time alignment to compensate for the limited digital time resolution of the present electronics. A preliminary version of scatter correction for TOF has been devised and is presented. The measured time resolution of 1.2 ns (FWHM) allowed for a signal-to-noise ratio increase of about 50% in phantoms of about 40 cm transaxial size, or a gain larger than 2 in noise equivalent counts (NEC). TOF reconstruction has shown the expected improvement in SNR, both in simulation and experimental data. First experimental results show two improvements of TOF reconstruction over conventional (non-TOF) reconstruction: a lower noise level and a better capability to resolve structures deep inside large objects.Keywords
This publication has 21 references indexed in Scilit:
- Fourier rebinning of time-of-flight PET dataPhysics in Medicine & Biology, 2005
- Time of flight in PET revisitedIEEE Transactions on Nuclear Science, 2003
- Time-of-flight PETSeminars in Nuclear Medicine, 1998
- Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillatorIEEE Transactions on Nuclear Science, 1992
- Three-dimensional PET reconstruction with time-of-flight measurementPhysics in Medicine & Biology, 1992
- Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomographIEEE Transactions on Nuclear Science, 1990
- Fast methods for including attenuation in the EM algorithmIEEE Transactions on Nuclear Science, 1990
- Performance measurements of the SP3000/UW time-of-flight positron emission tomographIEEE Transactions on Nuclear Science, 1988
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1986
- Barium fluoride — Inorganic scintillator for subnanosecond timingNuclear Instruments and Methods in Physics Research, 1983