Time of flight in PET revisited
Top Cited Papers
- 14 October 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 50 (5) , 1325-1330
- https://doi.org/10.1109/tns.2003.817319
Abstract
PET scanners based on LSO have the potential for significantly better coincidence timing resolution than the 6 ns FWHM typically achieved with BGO. This study analyzes the performance enhancements made possible by improved timing as a function of the coincidence time resolution. If 500 ps FWHM coincidence timing resolution can be achieved in a complete PET camera, the following four benefits can be realized for whole-body FDG imaging: 1) the random event rate can be reduced by using a narrower coincidence timing window, increasing the peak NECR by /spl sim/50%; 2) using time-of-flight (TOF) in the reconstruction algorithm will reduce the noise variance by a factor of 5; 3) emission and transmission data can be acquired simultaneously, reducing the total scan time; and 4) axial blurring can be reduced by using TOF to determine the correct axial plane of origin for each event. While TOF was extensively studied in the 1980s, practical factors limited its effectiveness at that time and little attention has been paid to timing in PET since then. As these potential improvements are substantial and the advent of LSO PET cameras gives us the means to obtain them without other sacrifices, efforts to improve PET timing should resume after their long dormancy.Keywords
This publication has 28 references indexed in Scilit:
- High-energy-resolution scintillator: Ce3+ activated LaBr3Applied Physics Letters, 2001
- LuAlO/sub 3/:Ce and other aluminate scintillatorsIEEE Transactions on Nuclear Science, 1995
- LuAlO/sub 3/:Ce-a high density, high speed scintillator for gamma detectionIEEE Transactions on Nuclear Science, 1995
- Results of a Comparative Study of a Reconstruction Procedure for Producing Improved Estimates of Radioactivity Distributions in Time-of-Flight Emission TomographyIEEE Transactions on Nuclear Science, 1984
- Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1983
- Effect of the Software Coincidence Timing Window in Time-of-Flight Assisted Positron Emission TomographyIEEE Transactions on Nuclear Science, 1983
- A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1981
- Image Reconstruction and Noise Evaluation in Photon Time-of-Flight Assisted Positron Emission TomographyIEEE Transactions on Nuclear Science, 1981
- A Positron-Emission Transaxial Tomograph for Nuclear Imaging (PETT)Radiology, 1975
- Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier TransformsProceedings of the National Academy of Sciences, 1971