Improved Performance of Bayesian Solutions for Inverse Electrocardiography Using Multiple Information Sources
- 18 September 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (10) , 2024-2034
- https://doi.org/10.1109/tbme.2006.881776
Abstract
The usual goal in inverse electrocardiography (ECG) is to reconstruct cardiac electrical sources from body surface potentials and a mathematical model that relates the sources to the measurements. Due to attenuation and smoothing that occurs in the thorax, the inverse ECG problem is ill-posed and imposition of a priori constraints is needed to combat this ill-posedness. When the problem is posed in terms of reconstructing heart surface potentials, solutions have not yet achieved clinical utility; limitations include the limited availability of good a priori information about the solution and the lack of a "good" error metric. We describe an approach that combines body surface measurements and standard forward models with two additional information sources: statistical prior information about epicardial potential distributions and sparse simultaneous measurements of epicardial potentials made with multielectrode coronary venous catheters. We employ a Bayesian methodology which offers a general way to incorporate these information sources and additionally provides statistical performance analysis tools. In a simulation study, we first compare solutions using one or more of these information sources. Then, we study the effects of varying the number of sparse epicardial potential measurements on reconstruction accuracy. To evaluate accuracy, we used the Bayesian error covariance as well as traditional error metrics such as relative error. Our results show that including even sparsely sampled information from coronary venous catheters can substantially improve the reconstruction of epicardial potential distributions and that a Bayesian framework provides a feasible approach to using this information. Moreover, computing the Bayesian error standard deviations offers a means to indicate confidence in the results even in the absence of validation dataKeywords
This publication has 31 references indexed in Scilit:
- The temporal prior in bioelectromagnetic source imaging problemsIEEE Transactions on Biomedical Engineering, 2003
- Combined Epicardial and Endocardial Electroanatomic Mapping in a Porcine Model of Healed Myocardial InfarctionCirculation, 2003
- A new treatment of the inverse problem of multivariate analysisInverse Problems, 2002
- The use of the spatial covariance in computing pericardial potentialsIEEE Transactions on Biomedical Engineering, 1999
- MEG-based imaging of focal neuronal current sourcesIEEE Transactions on Medical Imaging, 1997
- Sensitivity distributions of EEG and MEG measurementsIEEE Transactions on Biomedical Engineering, 1997
- Application of an Electrocardiographic Inverse Solution to Localize Ischemia During Coronary AngioplastyJournal of Cardiovascular Electrophysiology, 1995
- Error bounds for EEG and MEG dipole source localizationElectroencephalography and Clinical Neurophysiology, 1993
- Inverse calculation of QRS-T epicardial potentials from body surface potential distributions for normal and ectopic beats in the intact dog.Circulation Research, 1978
- Relating Epicardial to Body Surface Potential Distributions by Means of Transfer Coefficients Based on Geometry MeasurementsIEEE Transactions on Biomedical Engineering, 1977