Abstract
Cardiac output (CO) determination based on partial CO2 rebreathing has recently been introduced into clinical practice. The determination of flow is crucial for exact CO readings and the physical properties of xenon, i.e. high density and viscosity, may influence flow readings. This study compared echocardiography‐derived CO measurements with the partial rebreathing method during total intravenous (TIVA) vs. xenon‐based anaesthesia. Thirty‐nine patients ASA physical status III undergoing aortic reconstruction were randomly assigned to receive either xenon (Xe, n = 20) or TIVA (T, n = 19) based general anaesthetic. Paired measurements were taken before xenon administration, after xenon administration, before and after clamping of the abdominal aorta and after declamping and at corresponding time points in the TIVA group. Data were analysed with a Bland‐Altmann plot. Bias and precision were acceptable and comparable before xenon administration (T 0.54 ± 0.92 l.min−1 vs. Xe 0.11 ± 1.1 l.min−1), but after xenon administration CO was largely overestimated by partial CO2 rebreathing (T 0.04 ± 0.91 l.min−1 vs. Xe −4.0 ± 2.1 l.min−1). In the TIVA group, bias and precision after declamping increased significantly (P < 0.01) compared to all time points except baseline. In its current application, the NICO cardiac output monitor appears to be inappropriate for determination of CO during xenon based anaesthesia.Keywords
This publication has 27 references indexed in Scilit:
- Multicenter Randomized Comparison of the Efficacy and Safety of Xenon and Isoflurane in Patients Undergoing Elective SurgeryAnesthesiology, 2003
- "Partielle CO 2 -Rückatmungstechnik" versus Thermodilution Bestimmung des Herzzeitvolumens vor und nachDer Anaesthesist, 2002
- Is the placement of a pulmonary artery catheter still justified solely for the measurement of cardiac output?Journal of Cardiothoracic and Vascular Anesthesia, 2000
- Respiratory Mechanics during Xenon Anesthesia in PigsAnesthesiology, 1999
- Intraoperative Determination of Cardiac Output Using Multiplane Transesophageal EchocardiographyAnesthesiology, 1998
- The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT InvestigatorsJAMA, 1996
- Pulmonary resistance in dogs: a comparison of xenon with nitrous oxideCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1995
- Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic ValveAnesthesiology, 1994
- Safety and efficacy of xenon in routine use as an inhalational anaestheticThe Lancet, 1990
- Thermodilution cardiac output determination with a single flow-directed catheterAmerican Heart Journal, 1972