The New Hematology Analyzer Sysmex XE-2100
Open Access
- 1 March 2001
- journal article
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 125 (3) , 391-396
- https://doi.org/10.5858/2001-125-0391-tnhasx
Abstract
Context.—The new hematology analyzer Sysmex XE-2100 (TOA Medical Electronics, Kobe, Japan) has a novel, combined, white blood cell differential technology and a special reagent system to enumerate nucleated red blood cells. Design.—Performance evaluation of both technologies of the Sysmex XE-2100 according to the H20-A protocol of the National Committee for Clinical and Laboratory Standards and comparison of the results with those for the hematology analyzer Sysmex NE-8000 (TOA Medical Electronics). Specimens.—Five hundred forty-four blood samples randomly chosen from various inpatient and outpatient departments of the Vienna University hospital. Results.—Five-part white blood cell differential counts on the XE-2100 revealed excellent correlation with the manual reference method for neutrophils, lymphocytes, and eosinophils (r = .925, .922, and .877, respectively) and good correlation for monocytes and basophils (r = .756 and .763, respectively). The efficiency rates of flagging for the presence of ≥1% abnormal white blood cells were 83% (XE-2100) and 66% (NE-8000). The correlation of automated and microscopic nucleated red blood cell counts was excellent (r = .97). Conclusions.—From the present evaluation and our former experience with other types of Sysmex analyzers, we conclude that the new white blood cell differential technology of the XE-2100 represents a further development toward more efficient flagging of abnormal white blood cells.Keywords
This publication has 14 references indexed in Scilit:
- Nucleated red blood cell count at birth as an index of perinatal brain damageAmerican Journal of Obstetrics and Gynecology, 1999
- Preliminary Evaluation of the New Hematology Analyzer COULTER® GEN•S™ in a University Hospitalcclm, 1999
- Simultaneous differentiation and quantitation of erythroblasts and white blood cells on a high throughput clinical haematology analyserClinical and Laboratory Haematology, 1998
- Sysmex SE-9000 Hematology Analyzer:Performance Evaluation on Leukocyte Differential Counts Using an NCCLS H20-A ProtocolAmerican Journal of Clinical Pathology, 1997
- Evaluation of RBC ferritin and reticulocyte measurements in monitoring response to intravenous iron therapyAmerican Journal of Kidney Diseases, 1997
- Nucleated red blood cells: An update on the marker for fetal asphyxiaAmerican Journal of Obstetrics and Gynecology, 1996
- Quantitative assessment of erythropoiesis in haemodialysis patients demonstrates gradual expansion of erythroblasts during constant reatment with recombinant human erythropoietinBritish Journal of Haematology, 1995
- Laboratory and Clinical Evaluation of White Blood Cell Differential Counts: Comparison of the Coulter VCS, Technicon H-1, and 800 Cell Manual MethodAmerican Journal of Clinical Pathology, 1991
- Monocyte counting: discrepancies in results obtained with different automated instruments.Journal of Clinical Pathology, 1991
- SPECTRAL MATCHING OF CLASSICAL CYTOCHEMISTRY TO AUTOMATED CYTOLOGYJournal of Histochemistry & Cytochemistry, 1974