Experimental study of breakdown voltage-time characteristics of large air gaps with lightning impulses
- 1 January 1977
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. 96 (1) , 227-233
- https://doi.org/10.1109/t-pas.1977.32328
Abstract
This study reports mainly two points about the breakdown voltage - time characteristics of 1 - 5 m rod-plane and rod - rod gaps with lightning impulses. It is shown, at first, that the breakdown time follows the logarithmic normal distribution with a constant impulse level and that the probability of the breakdown time can be determined by empirical equation from the mean breakdown time and its standard deviation. The second part covers the breakdown phenomena with lightning impulses, delineating the development of streamers and leaders in relation to breakdown time. Estimates on basis of breakdown processes are made to breakdown time with impulses of short tail waves.Keywords
This publication has 10 references indexed in Scilit:
- Breakdown process of long air gaps with positive switching impulsesIEEE Transactions on Power Apparatus and Systems, 1975
- Experimental and Analytical Studies of the Effect of Non-Standard Waveshapes on the Impulse Strength of External InsulationIEEE Transactions on Power Apparatus and Systems, 1973
- Transition from the Primary Streamer to the Arc in Positive Point-to-Plane CoronaJournal of Applied Physics, 1971
- Four-Meter Sparks in AirJournal of Applied Physics, 1968
- Switching Surge and Impulse Sparkover Characteristics of Large Gap Spacings and Long Insulator StringsIEEE Transactions on Power Apparatus and Systems, 1965
- Mechanism of Breakdown of Laboratory GapsTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1961
- Surge voltage breakdown of air in a nonuniform fieldJournal of Research of the National Bureau of Standards, 1956
- Evaluation of the Integration Method for Analysis of Nonstandard Surge Voltages [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1954
- Surge Protection of Cable-Connected EquipmentTransactions of the American Institute of Electrical Engineers, 1950
- Volt-Time Areas of Impulse Spark-OverTransactions of the American Institute of Electrical Engineers, 1941