Design and Evaluation of a Positron Emission Tomograph
- 1 September 1985
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 9 (5) , 931-939
- https://doi.org/10.1097/00004728-198509000-00017
Abstract
A high performance positron emission tomograph, HEADTOME III, with 480 bismuth germanate oxide detectors (13.4 × 25.0 × 40.0 mm), arranged in three rings of 750 mm diameter, with independent shadow masks and septa, is described. Image plane resolution at the center of the field of view (FOV) is 7.9 and 6.5 mm full width at half maximum (FWHM) in low resolution (LR) and high resolution (HR) mode, respectively. Axial resolution is 13.1, 11.3, and 9.1 mm FWHM at the center of FOV for direct planes of low quantitation (LQ). cross planes of LQ, and high quantitation (HQ) mode, respectively. Sensitivities evaluated by true events for a 68Ga 20 cm diameter cyclindrical pool were 34.5 (56.7), 16.4 (27.5), 19.4 and 9.5 kcps (μCi/ml)-1 with the direct (cross) planes of LQLR, direct (cross) planes of LQHR, and direct planes of HQLR and HQHR, respectively. The fraction of scattered coincidence in a cold spot phantom after software correction is 2.5% in LRLQ mode. Count rate linearity after software correction is within 1% up to 50 × 103 true events per second per plane with LRLQ mode.Keywords
This publication has 11 references indexed in Scilit:
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1982
- Analytical Study of the Performance of a Multilayer Positron Computed Tomography ScannerJournal of Computer Assisted Tomography, 1982
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1981
- HEADTOMEJournal of Computer Assisted Tomography, 1981
- Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1980
- Noninvasive determination of local cerebral metabolic rate of glucose in manAmerican Journal of Physiology-Endocrinology and Metabolism, 1980
- Two Methods for Calculating Regional Cerebral Blood Flow from Emission Computed Tomography of Inert Gas ConcentrationsJournal of Computer Assisted Tomography, 1979
- The [18F]fluorodeoxyglucose method for the measurement of local cerebral glucose utilization in man.Circulation Research, 1979
- Transverse section imaging of mean clearance timePhysics in Medicine & Biology, 1978