Tissue Temperature‐Controlled Radiofrequency Ablation
- 1 March 2003
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (3) , 725-730
- https://doi.org/10.1046/j.1460-9592.2003.00123.x
Abstract
During radiofrequency energy delivery, the catheter tip temperature can be significantly lower than the tissue temperature. The authors performed tissue temperature-controlled radiofrequency ablation in vitro and evaluated the effects of cooling, electrode to tissue contact, and target tissue temperature on lesion size. Pieces of porcine ventricle were immersed in a bath of isotonic saline solution at 37 degrees C. Radiofrequency energy was controlled by the tissue temperature as measured with a thermocouple needle placed 2 mm beneath the ablation electrode. Radiofrequency power was delivered for 30 seconds and limited to 50 W. A total of 81 radiofrequency ablations was performed with different electrode to tissue contact forces (0.04 N, 0.36 N, and 0.67 N) and target tissue temperatures (50 degrees C, 60 degrees C, and 70 degrees C) using an irrigated (27 ablations, 20 mL/min irrigation flow rate) or a nonirrigated ablation catheter. Twenty-seven nonirrigated applications were performed with fluid flow maintained by the pump of the thermostat and another 27 applications without flow. Every combination was applied three times and the average values were used for evaluation. For tissue target temperatures of 50 degrees C, 60 degrees C, and 70 degrees C, the lesion volume for nonirrigated ablations was on average 21 +/- 8 mm3, 45 +/- 23 mm3, and 109 +/- 45 mm3, respectively, and for irrigated ablations 12 +/- 7 mm3, 37 +/- 20 mm3, and 92 +/- 30 mm3, respectively. In both application groups the lesion size did not correlate with the electrode to tissue contact force. In the nonirrigated ablation group there was no difference in lesion size between the group with fluid flow and those without. Lesion size during tissue temperature-controlled radiofrequency delivery increases with increasing target tissue temperature and becomes independent of flow and electrode to tissue contact.Keywords
This publication has 12 references indexed in Scilit:
- Mechanisms for Enlarging Lesion Size During Irrigated Tip Radiofrequency Ablation:. Is There a Virtual Electrode Effect?Journal of Interventional Cardiology, 2004
- Popping Phenomena in Temperature‐Controlled Radiofrequency Ablation: When and Why Do They Occur?Pacing and Clinical Electrophysiology, 2000
- Tissue Temperatures and Lesion Size During Irrigated Tip Catheter Radiofrequency Ablation: An In Vitro Comparison of Temperature‐Controlled Irrigated Tip Ablation, Power‐Controlled Irrigated Tip Ablation, and Standard Temperature‐Controlled AblationPacing and Clinical Electrophysiology, 2000
- Comparison of Standard and Irrigated Radiofrequency Ablation in the Canine VentricleJournal of Cardiovascular Electrophysiology, 1998
- The LETR‐Principle: A Novel Method to Assess Electrode‐Tissue Contact in Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 1998
- Inverse Relationship Between Electrode Size and Lesion Size During Radiofrequency Ablation With Active Electrode CoolingCirculation, 1998
- Lesion Size in Relation to Ablation Site During Radiofrequency AblationPacing and Clinical Electrophysiology, 1998
- Temperature-guided radiofrequency catheter ablation with very large distal electrodes.Circulation, 1993
- Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy DeliveryJournal of Cardiovascular Electrophysiology, 1991
- Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium.Circulation, 1990